Terug naar: Reizende kabels



FH Module Concept – Low Fire Hazard
Drawing according to article number 191114 - Type 8859-F




Beschrijving
Elevator suspension cable for indoor and panoramic elevators
- To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately.
- Bedrijfstemperatuur -15 °C - +70 °C
- Mantelkleur zwart
- Buitenmantel low fire hazard
- Bundel with black sheath
- Coax zwart
- Kern black, white numbered, G = with green-yellow core(s)
- Optische vezels orange 50 Μm, grey 62.5 Μm
- Pair/quad various colours or black with white numbers,
- Core flexibel class 5
- Ader isolatie low fire hazard
- Ondersteunende leden ST = Steel, diameter in [mm]
- Nominale spanning Uo/U according to table
- Maximale vrije schorsing 220 m
- Versnelling 1.2 m/s²
- Maximale loopsnelheid 12 m/s
- Maximale reishoogte 400 m
- Aanbevolen lusdiameter approx. 650 mm, tolerance -50/+150 mm
- Standaard voor flexibele besturingskabels voor liften EN 50214