Terug naar: Reizende kabels



FL – Low Fire Hazard – unsupported
Drawing according to article number 191113 - Type 8582-F




Beschrijving
Elevator suspension cable for indoor and panoramic elevators.
- To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
- Bedrijfstemperatuur -15 °C - +70 °C
- Mantelkleur zwart
- Buitenmantel low fire hazard
- Coax zwart
- Kern black, white numbered, G = with green-yellow core(s)
- Pair/quad various colours or black with white numbers
- Core flexibel class 5
- Ader isolatie low fire hazard
- Ondersteunende leden none
- Nominale spanning Uo/U according to table
- Maximale vrije schorsing 45 m
- Versnelling 0.8 m/s²
- Maximale loopsnelheid 4 m/s
- Maximale reishoogte 80 m
- Aanbevolen lusdiameter according to table, tolerance -50/+100 mm
- Standaard voor flexibele besturingskabels voor liften EN 50214
Documentatie
Versies
Artikelnr. | Voorraad | Artikel | Kabelontwerp | Cu tarief [kg/km] | Gewicht [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
191110
|
8511-F | 12 G 0.75 mm² | 87 | 259 | 40393910069716 | |
185125
|
8511-F | 18 G 0.75 mm² | 130 | 382 | 40393910077353 | |
191112
|
8511-F | 24 G 0.75 mm² | 173 | 511 | 40393910069693 | |
191111
|
8636-F | 12 G 0.75 + 3 x 2 x 0.50 mm² (FTP) | 123 | 420 | 40393910069709 | |
182205
|
8827-F | 3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.34 mm² (FTP) | 244 | 735 | 40393910077766 | |
191113
|
8582-F | 24 G 1.00 + 3 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 306 | 958 | 40393910069686 | |
190491
|
8582-F | 2 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 1 CX 75 Ω | 149 | 524 | 40393910070873 |