Terug naar: Veiligheidskabels

FE180 E30 CL

halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H

1 Conductor: solid / stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Inner Sheath: Polyolefin flame retardant, low smoke, zero halogen
6 Armouring: galvanised steel tape
7 Sheath: FRNC/LSZH

Beschrijving

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90˚C.

  • Installatietemperatuur -5 °C - +50 °C
  • Bedrijfstemperatuur -45 °C - +90 °C
  • Circuit Integriteit E30
  • Integriteit van de isolatie FE 180
  • Buitenmantel Compound, HD 604 S1 part 5 H(16 mm2: in accordance with CENELEC HD 308 S2 and VDE 0293)
  • Bewapening (bescherming tegen knaagdieren) Eenaderige kabel met koperband (CLCU) en meeraderige kabel met gegalvaniseerde staalband (CL)
  • Geleider Blanke koperkern, massief of samengeslagen, volgens IEC 60228 en EN 60228 (≥16 mm2: volgens VDE 0295)
  • Aderkleuren CENELEC HD 308 S2
  • Opvulling HD 604 S1 part 5 H (≥16 mm2: speciale verbinding, vlamvertragend, halogeenvrij)
  • Binnenmantel Verbinding volgens HD 604 S1 part 5 H (≥16 mm2: verbinding volgens VDE 0276-604, CENELEC HD 604 S1 "HM 4", vlamvertragend)
  • Aderisolatie Vernet polymeer volgensHD 604 S1 part 5 H (≥16 mm2: dubbellelaag-isolatie, vernet polymeer volgens VDE 0266 "HXI1"
  • Testspanning bij 50Hz 3500 V
  • Minimale buiging tijdens installatie (enkele kern) 15 x D
  • Minimale buiging tijdens installatie (multi-core) 12 x D
  • Minimale buigradius permanent (enkele kern) 15 x D
  • Minimale buigradius permanent (multi-core) 12 x D
  • * System Circuit Integrity is dependent on installation method
  • Nulhalogeen geen corrosieve gassen EN 60754-1/-2, IEC 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA, SEV TPV11
  • Vlamdovend EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1, SEV TP 20B/3C 3.4.1.1
  • Vlam verspreid EN 60332-3-24 Cat. C, IEC 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C, AREI-RGIE Art.104-F2, SEV TP 20B/3C 3.4.1.3
  • Rookdichtheid EN 61034-1/-2, IEC 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD, SEV TP 20B/3C 3.4.3
  • Functiebehoud DIN 4102-12, AREI-RGIE Art.104-FR2
  • Isolatiebehoud (FE180) IEC 60331-11/-21 (180 Notulen), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 Notulen), IEC 60331-2 (120 Notulen), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), VDE 0482-362, AREI-RGIE Art.104-FR1

Documentatie

ENDENLFRCNESIT
ProductDatasheet ProductDatasheet ProductDatasheet ProductDatasheet ProductDatasheet file-icon ProductDatasheet ProductDatasheet

Versies

Artikelnr.VoorraadArtikelAantal kernenDiameter mm²Buitenmanteldiameter [mm]Cu tarief [kg/km]Gewicht [kg/km]Brandlast [kWh/m]GeleiderGTIN
193886 FE180 E30 CL31.511432100.46 kWh/mmassief40393910065367
187199 FE180 E30 CL32.512722550.50 kWh/mmassief40393910074345
191097 FE180 E30 CL34141153730.69 kWh/mmassief40393910069785
191121 FE180 E30 CL3615.81734810.90 kWh/mmassief40393910069648
188354 FE180 E30 CL310182886511.20 kWh/mmassief40393910072303
191595 FE180 E30 CL42.514962960.56 kWh/mmassief40393910069143
187167 FE180 E30 CL44161544080.79 kWh/mmassief40393910074512
188352 FE180 E30 CL46172305351.06 kWh/mmassief40393910072327
191038 FE180 E30 CL52.5141203880.76 kWh/mmassief40393910070040
188350 FE180 E30 CL54161924881.05 kWh/mmassief40393910072341
188353 FE180 E30 CL5617.52886401.28 kWh/mmassief40393910072310
188397 FE180 E30 CL510214809641.76 kWh/mmassief40393910072082
187197 FE180 E30 CL72.5161684760.91 kWh/mmassief40393910074369
188355 FE180 E30 CL76194037941.53 kWh/mmassief40393910072297
188356 FE180 E30 CL7102367212012.13 kWh/mmassief40393910072280
192461 FE180 E30 CL81.5151154030.85 kWh/mmassief40393910067477
187128 FE180 E30 CL82.5161924891.04 kWh/mmassief40393910074642
191104 FE180 E30 CL84183086841.36 kWh/mmassief40393910069754
Additional dimensions available on request