Tornare a: Cavi mobili

FH Module Concept – Low Fire Hazard

High rise – travelling height maximum 400m

Drawing according to article number 191114 - Type 8859-F

Descrizione

Elevator suspension cable for indoor and panoramic elevators

  • To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately.
  • Outer sheath colour nera
  • Outer sheath material low fire hazard
  • Core flexible class 5
  • Core insulation low fire hazard
  • Supporting members ST = Steel, diameter in [mm]
  • Standard per cavi flessibili di controllo dell'ascensore EN 50214
  • Rated voltage Uo/U according to table
  • Operating temperature -15 °C - +70 °C
  • Bundle with black sheath
  • Coax nera
  • Core black, white numbered, G = with green-yellow core(s)
  • Optical fibres orange 50 Μm, grey 62.5 Μm
  • Pair/quad various colours or black with white numbers,
  • Maximum free suspension 220 m
  • Maximum free suspension 220 米
  • Acceleration 1.2 m/s²
  • Maximum running speed 12 m/s
  • Maximum travelling height 400 米
  • Maximum travelling height 400 m
  • Recommended loop diameter approx. 650 mm, tolerance -50/+150 mm

Documentazione

EN DE NL FR CN ES IT
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica

Versioni

Article No. Magazzino Prodotto Tasso di CU [kg\km]Weight [kg\km]
191114 8859-F 698 kg/km1929
191483 8866-F 616 kg/km2184