Tornare a: Cavi di sicurezza

J-H(St)H...Bd fire alarm

halogen-free, with improved fire characteristics,
VDE 0815

1 Conductor: solid
2 Insulatio: halogen-free polymer compound
3 Separator: plastic tape
4 Drain wire: tinned copper
5 Shielding: Al-laminated plastic foil
6 Sheath: FRNC/LSZH

Descrizione

Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms, on-wall and in-wall, also for outdoor use.
No underground laying. Not to be used for high-voltage transmission.
Permitted operating temperature at conductor of +70°C.

  • Conduttore Bare copper, solid, 0.6 or 0.8 mm diameter
  • Colori delle anime DIN VDE 0815
  • Isolamento Halogen-free polymer compound, EN 50290-2-26
  • Shielding Al-laminated plastic foil with drain wire, copper tinned
  • Stranding Cores twisted to star-quads and quads to units
  • Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Propagazione della fiamma IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
  • Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
  • Additional dimensions available on request.
  • Capacitive coupling 0,6 mm, 100m @ 800Hz 300 pF/km
  • Capacitive coupling 0,8 mm, 100m @ 800Hz 200 pF/km
  • resistenza massima del loop 0,6 mm 130 Ω/km
  • resistenza massima del loop 0,8 mm 73.2 Ω/km
  • Minimum insulation resistance 100 MΩ x km
  • operating capacity, 1km @ 800Hz 120 nF/km
  • peak voltage 300 V
  • Test voltage 50Hz, core/core 800 V
  • Test voltage 50Hz, core/screen 800 V
  • Installation temperature -5 °C - +50 °C
  • Operating temperature -30 °C - +70 °C
  • Materiale della guaina esterna Halogen-free polymer compound, EN 50290-2-27
  • Integrità del circuito No
  • Integrità dell'isolamento No
  • Curvatura minima durante l'installazione (multicore) 7.5 x D
  • Minimum bending radius permanent (multi core) 2.5 x D

Documentazione

EN DE NL FR CN ES IT
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica

Versioni

Article No. Magazzino Prodotto Colore della guaina esternaNumero di coppieNumero di coreDiametro mmDiametro esterno della guaina [mm]Tasso di CU [kg/km]Weight [kg/km]Fire load [kWh/m]Unità di imballaggioGTIN / EAN
157892 J-H(St)H...Bd fire alarm 2x2x0,8 mm rosso 2 2 0.8 mm6.5 25 59 0.16 kWh/mal metro 40393910207637
157893 J-H(St)H...Bd fire alarm 4x2x0,8 mm rosso 4 2 0.8 mm8.5 45 111 0.29 kWh/mal metro 40393910207620
157894 J-H(St)H...Bd fire alarm 6x2x0,8 mm rosso 6 2 0.8 mm10.5 65 132 0.35 kWh/mal metro 40393910207613
157895 J-H(St)H...Bd fire alarm 10x2x0,8 mm rosso 10 2 0.8 mm13 106 216 0.55 kWh/mal metro 40393910207606
1172017 J-H(St)H...Bd fire alarm 20x2x0,8 mm rosso 20 2 0.8 mm15.5 206 508 1.21 kWh/mal metro 40393910107104
1172018 J-H(St)H...Bd fire alarm 30x2x0,8 mm rosso 30 2 0.8 mm16.3 307 599 1.36 kWh/mal metro 40393910107098
1172019 J-H(St)H...Bd fire alarm 40x2x0,8 mm rosso 40 2 0.8 mm16.5 407 787 1.67 kWh/mal metro 40393910107081
1172021 J-H(St)H...Bd fire alarm 80x2x0,8 mm rosso 80 2 0.8 mm31.5 809 1476 3.18 kWh/mal metro 40393910107074
1172022 J-H(St)H...Bd fire alarm 100x2x0,8 mm rosso 100 2 0.8 mm38 1010 1805 4.07 kWh/mal metro 40393910107067