J-H(St)H...Bd fire alarm
halogen-free, with improved fire characteristics,
VDE 0815
1 Conductor: solid
2 Insulatio: halogen-free polymer compound
3 Separator: plastic tape
4 Drain wire: tinned copper
5 Shielding: Al-laminated plastic foil
6 Sheath: FRNC/LSZH






Descrizione
Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms, on-wall and in-wall, also for outdoor use.
No underground laying. Not to be used for high-voltage transmission.
Permitted operating temperature at conductor of +70°C.
- Stranding Cores twisted to star-quads and quads to units
- Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
- Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
- Propagazione della fiamma AREI-RGIE Art.104-F1, EN 60332-1-2, IEC 60332-1-2, VDE 0482-332-1-2
- Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
- Capacitive coupling 0,6 mm, 100m @ 800Hz 300 pF/km
- Capacitive coupling 0,8 mm, 100m @ 800Hz 200 pF/km
- resistenza massima del loop 0,6 mm 130 Ω/km
- resistenza massima del loop 0,8 mm 73.2 Ω/km
- Minimum insulation resistance 100 MΩ x km
- operating capacity, 1km @ 800Hz 120 nF/km
- peak voltage 300 V
- Test voltage 50Hz, core/core 800 V
- Test voltage 50Hz, core/screen 800 V
- Installation temperature -5 °C - +50 °C
- Operating temperature -30 °C - +70 °C
- Integrità del circuito Nein
- Integrità dell'isolamento No
- Curvatura minima durante l'installazione (multicore) 7.5 x D
- Minimum bending radius permanent (multi core) 2.5 x D
Documentazione
Versioni
Article No. | Magazzino | Prodotto | Colore della guaina esterna | Numero di coppie | Numero di core | Diametro mm | Diametro esterno della guaina [mm] | Tasso di CU [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Unità di imballaggio | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|
157892
|
J-H(St)H...Bd fire alarm 2x2x0,8 mm | rosso | 2 | 2 | 0.8 | 6.5 | 25 | 59 | 0.16 kWh/m | al metro | 40393910207637 | |
157893
|
J-H(St)H...Bd fire alarm 4x2x0,8 mm | rosso | 4 | 2 | 0.8 | 8.5 | 45 | 111 | 0.29 kWh/m | al metro | 40393910207620 | |
157894
|
J-H(St)H...Bd fire alarm 6x2x0,8 mm | rosso | 6 | 2 | 0.8 | 10.5 | 65 | 132 | 0.35 kWh/m | al metro | 40393910207613 | |
157895
|
J-H(St)H...Bd fire alarm 10x2x0,8 mm | rosso | 10 | 2 | 0.8 | 13 | 106 | 216 | 0.55 kWh/m | al metro | 40393910207606 | |
1172017
|
J-H(St)H...Bd fire alarm 20x2x0,8 mm | rosso | 20 | 2 | 0.8 | 15.5 | 206 | 508 | 1.21 kWh/m | al metro | 40393910107104 | |
1172018
|
J-H(St)H...Bd fire alarm 30x2x0,8 mm | rosso | 30 | 2 | 0.8 | 16.3 | 307 | 599 | 1.36 kWh/m | al metro | 40393910107098 | |
1172019
|
J-H(St)H...Bd fire alarm 40x2x0,8 mm | rosso | 40 | 2 | 0.8 | 16.5 | 407 | 787 | 1.67 kWh/m | al metro | 40393910107081 | |
1172021
|
J-H(St)H...Bd fire alarm 80x2x0,8 mm | rosso | 80 | 2 | 0.8 | 31.5 | 809 | 1476 | 3.18 kWh/m | al metro | 40393910107074 | |
1172022
|
J-H(St)H...Bd fire alarm 100x2x0,8 mm | rosso | 100 | 2 | 0.8 | 38 | 1010 | 1805 | 4.07 kWh/m | al metro | 40393910107067 |