Tornare a: Cavo esterno

FO Outdoor ZGGT HP / A-DQ(ZN)B2Y

central tube design, metal-free,
longitudinally watertight, rodent protection

1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 HDPE sheath

Descrizione

Robust, metal-free fibre optic outdoor cable with one central loose tube and up to 24 fibres.
High tensile strength and high radial load strength for the highest transmission security.
Lightweight and installation friendly cable construction.
Non-metallic rodent protection.
The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
HDPE cable sheath, easy to lay.

  • For pulling in or blowing through thermoplastic duct systems.
    Suitable for laying in cable platforms, cable shafts
    and even in very complex cable trays.
    Direct burial.
  • Armatura (protezione per roditori) protetto dai roditori
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Variazione di temperatura IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -40 °C - +70 °C
  • Operating temperature -40 °C - +70 °C
  • Massimo numero di fibre 24
  • Repeated bending IEC 60794-1-21 E6

Documentazione

EN DE NL FR CN ES IT
Certificati GHMT PVP Certificati GHMT PVP Certificati GHMT PVP file-icon file-icon file-icon file-icon file-icon
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica

Versioni

Article No. Magazzino Prodotto Reaction to fireColore della guaina esternaNumero di fibreFibre typeDiametro esterno della guaina [mm]Raggio di curvatura [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTIN / EANCategoria di fibraFibres per loose tubeLoose tube constructionNumber of used loose tubes
19016600FZ FO Outdoor HP 1x4 Fca nero 4 E9/125 G.652.D OS2 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910033588 OS2 4 1 1
19212100FZ FO Outdoor HP 1x4 Fca nero 4 G50/125 OM3 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910027792 OM3 4 1 1
19608900FZ FO Outdoor HP 1x4 Fca nero 4 G50/125 OM4 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910020045 OM4 4 1 1
19016700FZ FO Outdoor HP 1x6 Fca nero 6 E9/125 G.652.D OS2 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910033571 OS2 6 1 1
19074700FZ FO Outdoor HP 1x6 Fca nero 6 G50/125 OM3 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910032291 OM3 6 1 1
19016800FZ FO Outdoor HP 1x8 Fca nero 8 E9/125 G.652.D OS2 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910033564 OS2 8 1 1
19016900FZ FO Outdoor HP 1x12 Fca nero 12 E9/125 G.652.D OS2 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910033557 OS2 12 1 1
18636100FZ FO Outdoor HP 1x12 Fca nero 12 G50/125 OM3 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910039047 OM3 12 1 1
19261000FZ FO Outdoor HP 1x12 Fca nero 12 G50/125 OM4 8.2 130 75 2500 10000 6000 0.558 kWh/mal metro 40393910027280 OM4 12 1 1
19014900FZ FO Outdoor HP 1x24 Fca nero 24 E9/125 G.652.D OS2 8.6 135 80 2500 10000 6000 0.589 kWh/mal metro 40393910033656 OS2 24 1 1
19264500FZ FO Outdoor HP 1x24 Fca nero 24 G50/125 OM3 8.6 135 80 2500 10000 6000 0.589 kWh/mal metro 40393910027174 OM3 24 1 1
19216700FZ FO Outdoor HP 1x24 Fca nero 24 G50/125 OM4 8.6 135 80 2500 10000 6000 0.589 kWh/mal metro 40393910027648 OM4 24 1 1