Tornare a: cavo universale

FO Universal DLTS ZGGFR / U-BQ(ZN)BH

metal-free, dry interstices, gel-free loose tube,
rodent protection, flame redardant, longitudinally watertight

1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 FR/LS0H sheath

Descrizione

Robust, non-metallic fibre optic outdoor and indoor cable with one central dry loose tube.
High crush resistance for high transmission reliability.
Easy to handle due to cable construction with dry interstices and gel-free loose tubes.
Longitudinal water-tightness by swelling yarn.
Non-metallic rodent protection.
The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
Flame retardant halogen-free FR/LS0H sheath.

  • LAN backbone, access and riser zone.
    Connection cable between the building distributors and/or floor distributors.
    Suitable for laying in cable trays, ducts and vertical shafts.
    Can also be spliced in all FO distributors and joints.
  • Materiale della guaina esterna FRNC/LSZH
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Variazione di temperatura IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Dca
  • Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Propagazione della fiamma IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
  • Flame Spread IEC 60332-3-24
  • Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
  • Resistenza ai raggi UV EN 50289-4-17
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Campo di applicazione Universale
  • Impronta DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Massimo numero di fibre 24
  • Fibre colour code IEC 60304

Documentazione

EN DE NL FR CN ES IT
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica

Versioni

Article No. Magazzino Prodotto Reaction To FireColore della guaina esternaNumero di fibreFibre typeDiametro esterno della guaina [mm]Raggio di curvatura [mm]Weight [kg/km]Tensile load short term [N]Tensile load continuous [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTIN / EANCategoria di fibraFibres per loose tubeLoose tube constructionNumber of used loose tubes
19706600DZ FO Universal DLTS 1x4 Dca-s2,d1,a1 giallo 4 E9/125 G.652.D OS2 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910017113 OS2 4 1 1
19708000DZ FO Universal DLTS 1x4 Dca-s2,d1,a1 turchese 4 G50/125 OM3 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016963 OM3 4 1 1
19708500DZ FO Universal DLTS 1x4 Dca-s2,d1,a1 heather violet 4 G50/125 OM4 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016819 OM4 4 1 1
19706700DZ FO Universal DLTS 1x6 Dca-s2,d1,a1 giallo 6 E9/125 G.652.D OS2 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910017083 OS2 6 1 1
19708100DZ FO Universal DLTS 1x6 Dca-s2,d1,a1 turchese 6 G50/125 OM3 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016932 OM3 6 1 1
19708600DZ FO Universal DLTS 1x6 Dca-s2,d1,a1 heather violet 6 G50/125 OM4 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016789 OM4 6 1 1
19706800DZ FO Universal DLTS 1x8 Dca-s2,d1,a1 giallo 8 E9/125 G.652.D OS2 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910017052 OS2 8 1 1
19708200DZ FO Universal DLTS 1x8 Dca-s2,d1,a1 turchese 8 G50/125 OM3 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016901 OM3 8 1 1
19708700DZ FO Universal DLTS 1x8 Dca-s2,d1,a1 heather violet 8 G50/125 OM4 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016758 OM4 8 1 1
19618100DZ FO Universal DLTS 1x12 Dca-s2,d1,a1 giallo 12 E9/125 G.652.D OS2 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910019049 OS2 12 1 1
19708300DZ FO Universal DLTS 1x12 Dca-s2,d1,a1 turchese 12 G50/125 OM3 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910016871 OM3 12 1 1
19618500DZ FO Universal DLTS 1x12 Dca-s2,d1,a1 heather violet 12 G50/125 OM4 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910018882 OM4 12 1 1
19706400DZ FO Universal DLTS 1x12 Dca-s2,d1,a1 lime green 12 G50/125 OM5 7.6 mm115 mm68 3000 1000 5000 1000 0.234 kWh/mal metro 40393910017144 OM5 12 1 1
19618200DZ FO Universal DLTS 1x24 Dca-s2,d1,a1 giallo 24 E9/125 G.652.D OS2 8.2 mm125 mm78 3500 1500 5000 1000 0.325 kWh/mal metro 40393910018998 OS2 24 1 1
19708400DZ FO Universal DLTS 1x24 Dca-s2,d1,a1 turchese 24 G50/125 OM3 8.2 mm125 mm78 3500 1500 5000 1000 0.325 kWh/mal metro 40393910016840 OM3 24 1 1
19618600DZ FO Universal DLTS 1x24 Dca-s2,d1,a1 heather violet 24 G50/125 OM4 8.2 mm125 mm78 3500 1500 5000 1000 0.325 kWh/mal metro 40393910018837 OM4 24 1 1
19706500DZ FO Universal DLTS 1x24 Dca-s2,d1,a1 lime green 24 G50/125 OM5 8.2 mm125 mm78 3500 1500 5000 1000 0.325 kWh/mal metro 40393910210750 OM5 24 1 1