Tornare a: cavo universale

FO Universal wbGGFR Safety / U-DQ(ZN)BH

metal-free, water resistant, rodent protection,
in accordance with IEC 60332-1-2 and IEC 60332-3-24
30 minutes System Circuit Integrity* with reference to DIN 4102-12

1 ≤ 12 fibres
2 Flame retardant protective coating
3 Glass armour
4 Ripcord
5 FR/LS0H sheath

Descrizione

Metal-free fibre optic safety cable with multiple loose tubes, up to 60 fibres.
The optimal combination of flame retardant fibre coating and flame-inhibiting stabilizing elements ensures enhanced functional integrity (System Circuit Integrity*) in case of fire for 30 minutes (transmission of audio, video and 1Gbit/s signals approved by a certified test report).

  • Safety applications in tunnels, underground railways, banks, insurance companies, large-scale industry.
    LAN backbone.
    Indoor and outdoor cabling.
    Can also be installed in cable platforms, trays, ducts and vertical shafts (without System Circuit Integrity*).
    Can be spliced in FO distributors.
  • Materiale della guaina esterna FRNC/LSZH
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Variazione di temperatura IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Propagazione della fiamma IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
  • Flame Spread IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24
  • Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
  • Resistenza ai raggi UV EN 50289-4-17
  • * System Circuit Integrity is dependent on installation method. Certified clamps, ducts, conduits, etc. are mandatory.
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Campo di applicazione Universale
  • Impronta DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Massimo numero di fibre 72

Documentazione

EN DE NL FR CN ES IT AT
Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica Scheda tecnica file-icon Scheda tecnica Scheda tecnica Scheda tecnica

Versioni

Article No. Magazzino Prodotto Colore della guaina esternaNumero di fibreFibre typeDiametro esterno della guaina [mm]Raggio di curvatura [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Unità di imballaggioGTINCategoria di fibraFibres per loose tubeLoose tube constructionNumber of used loose tubes
194430 FO Universal Safety 1x12 rosso 12 E9/125 G.652.D OS2 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910064223 OS2 12 1 1
190223 FO Universal Safety 2x12 rosso 24 E9/125 G.652.D OS2 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910071238 OS2 12 2 2
187360 FO Universal Safety 2x12 rosso 24 G50/125 OM3 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910073904 OM3 12 2 2
193454 FO Universal Safety 2x12 rosso 24 G50/125 OM4 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910065466 OM4 12 2 2
190224 FO Universal Safety 3x12 rosso 36 E9/125 G.652.D OS2 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910071221 OS2 12 3 3
193455 FO Universal Safety 3x12 rosso 36 G50/125 OM4 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910065459 OM4 12 3 3
194575 FO Universal Safety 4x12 rosso 48 E9/125 G.652.D BLO 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910064063 OS2 12 4 4
190225 FO Universal Safety 4x12 rosso 48 E9/125 G.652.D OS2 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910071214 OS2 12 4 4
191191 FO Universal Safety 4x12 rosso 48 G50/125 OM3 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910069594 OM3 12 4 4
193456 FO Universal Safety 4x12 rosso 48 G50/125 OM4 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910065442 OM4 12 4 4
190226 FO Universal Safety 5x12 rosso 60 E9/125 G.652.D OS2 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910071207 OS2 12 5 5
190605 FO Universal Safety 5x12 rosso 60 G50/125 OM3 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910070514 OM3 12 5 5
193457 FO Universal Safety 5x12 rosso 60 G50/125 OM4 12.5 mm190 mm181 6000 5000 3000 0.733 kWh/mal metro 40393910065435 OM4 12 5 5