Tornare a: Cavi in rame










CU 6052 4P / 2x4P F8
300 MHz
1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Alu PETP foil
5 Drain wire: Tinned copper wire
6 Outer sheath: FRNC/LSOH Orange RAL 2003











Descrizione
Electrically and mechanically superior quality Cat.6 data cable – exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1.
Good shielding effect due to individually screened pairs and overall foil screen.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.
-
Data cable for structured premises cabling.
For the transmission of digital and analogue voice, video and data signals.
Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
Applicable for Power over Ethernet (PoE) / PoE+.
- Colore della guaina esterna arancia
- Materiale della guaina esterna FRNC/LSZH
- Reaction to fire (Euroclasses) EN 13501-6: Cca
- Zero alogeni nessun gas corrosivo IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
- Propagazione della fiamma IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
- Flame Spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
- Densità del fumo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
- Cat./Class Cat.6 / Class E
- PoE IEEE 802.3bt Type 4 (100W)
- Categoria Cat.6
- Attenuazione di accoppiamento 65 dB
- Ritardo Skew 5 ns/100 m
- Schermatura schermati
- GBit\s A 1 Gbit/s
- Impedenza a 100 MHz, ±5Ω 100 Ω
- Loop resistance at 20°C 150 Ω/km
- Near end unbalance attenuation LCL at 1-600 MHz 40 dB
- NVP % 79
- operating capacity 42 pF/m
-
Transfer impedance 1/10/30 MHz
50/100/200 mΩ/m
- Installation temperature 0 °C - +50 °C
- Operating temperature -20 °C - +60 °C
- Campo di applicazione Interno
- Impronta DATWYLER «cable type» «additional text» «batch number» «meter marks»
- Colore del filo bianco/blu, bianco/arancio, bianco/verde, bianco/marrone, in conformità alle norme IEC 60189 e IEC 60708
- AWG 23
- Curvatura minima durante l'installazione 56 mm
- Minimum bending radius permanently installed 28 mm
- Resistenza minima allo schiacciamento / 10cm 1000 N
- Minimum number of impacts 10
- Solid / Flex stabile
- Resistenza alla trazione (2x4P) 190 N
- Resistenza alla trazione (4P) 95 N
Documentazione
Versioni
Article No. | Magazzino | Prodotto | AWG | Reaction To Fire | Dimensions n x p x [mm (AWG)] | Numero di coppie | Numero di core | Diametro mm | Dimensioni della guaina esterna [mm] | Tasso di CU [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Number of cables | Unità di imballaggio | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18851200CK
|
CU 6052 4P | AWG23 | Cca-s1a,d1,a1 | 4 x 2 x 0.55 (AWG23) | 4 | 2 | 0.55 mm | 7 | 20.0 | 49 | 0.144 kWh/m | 1 | 1000 m tamburo | 40393910034370 |