Retour à: Câbles de sécurité

FE180 E30

halogen-free, with improved fire characteristics,
in accordance to SEV TP 20B/3C and CENELEC HD 604 S1 part 5.H
30 minutes system circuit integrity* with reference to DIN 4102-12

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Sheath: FRNC/LSZH

Description

Safety cables are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled.
Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90˚C.

  • Zéro halogène, pas de gaz corrosifs IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA, SEV TPV11
  • Propagation de flamme IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1, SEV TP 20B/3C 3.4.1.1
  • Propagation de la flamme IEC 60332-3-24 Cat. C, EN 60332-3-24 Cat. C, VDE 0482-332-3-24 Cat. C, AREI-RGIE Art.104-F2, SEV TP 20B/3C 3.4.1.3
  • Densité De Fumée IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD, SEV TP 20B/3C 3.4.3
  • Maintien de l'isolation (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), VDE 0482-362, AREI-RGIE Art.104-FR1
  • Température d'installation -5 °C - +50 °C
  • Température de fonctionnement -45 °C - +90 °C
  • Intégrité du circuit E30
  • Intégrité de l'isolation FE 180
  • Rayon de courbure minimal fixe (câble monoconducteur) 15 x D
  • Rayon de courbure minimal fixe (câbles multiconducteurs) 12 x D
  • Rayon de courbure minimal lors de l'installation (câble monoconducteur) 15 x D
  • Rayon de courbure minimal lors de l'installation (câbles multiconducteurs) 12 x D
  • Remarques sur le rayon de courbure 50% reduction if installation at 30°C and with a template
  • Tension d'essai à 50 Hz 3500 V
  • System Circuit Integrity is depemndent on installation method.

Documentation

ENDENLFRCNESIT
Fiche technique Fiche technique Fiche technique Fiche technique Fiche technique file-icon Fiche technique Fiche technique

Versions

N° d'articleStockProduitNombres de coeursDiameter mm²Diamètre de la gaine extérieure [mm]Poids CU [kg/km]Poids [kg/km]Charge d'incendie[kWh/m]ConducteurConstruction
191118 FE180 E30 2 x 1.521.57.8291020.22 kWh/mmassifLN
188360 FE180 E30 2 x 1,521.57.8291020.22 kWh/m2L
191119 FE180 E30 2 x 2.522.59481420.28 kWh/mmassifLN
190402 FE180 E30 2 x 2,522.59481422L
187180 FE180 E30 3 x 1.531.58.3431210.25 kWh/mmassifLNPE
187184 FE180 E30 3 x 2.532.59.5721690.31 kWh/mmassifLNPE
187187 FE180 E30 3 x 434111152430.41 kWh/mmassifLNPE
187189 FE180 E30 3 x 63612.51733290.51 kWh/mmassifLNPE
187182 FE180 E30 4 x 1.541.59.1581470.29 kWh/mmassif3LPE
190502 FE180 E30 4 x 2.542.510.5962090.38 kWh/mmassif3LPE
192352 FE180 E30 4 x 44412.21543040.49 kWh/mmassif3LPE
192353 FE180 E30 4 x 64613.82304090.61 kWh/mmassif3LPE
187183 FE180 E30 5 x 1.551.59.9721770.35 kWh/mmassif3LNPE
187186 FE180 E30 5 x 2.552.511.61202550.47 kWh/mmassif3LNPE
187188 FE180 E30 5 x 45413.41923710.61 kWh/mmassif3LNPE
187190 FE180 E30 5 x 65615.22885040.76 kWh/mmassif3LNPE
186267 FE180 E30 7 x 1.571.510.8100.82200.41 kWh/mmassif6LPE
186268 FE180 E30 7 x 2.572.512.51683190.53 kWh/mmassif6LPE
187201 FE180 E30 7 x 67616.74036440.89 kWh/mmassif6LPE
187108 FE180 E30 8 x 1.581.511.91152580.48 kWh/mmassif7LPE
188345 FE180 E30 10 x 1.5101.513.81443190.69 kWh/mmassif9LPE
186269 FE180 E30 12 x 1.5121.514.2172.83640.66 kWh/mmassif11LPE
192479 FE180 E30 12 x 2.5122.516.72885360.88 kWh/mmassif11LPE
187109 FE180 E30 21 x 1.5211.517.73035780.99 kWh/mmassif20LPE
190412 FE180 E30 27 x 1.5271.520.43897521.30 kWh/mmassif26LPE