Regresar a la: Cables de seguridad

(N)HXCH FE180 E30-E60 B2ca

halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E30-E60* in accordance with DIN 4102-12
Reacción al fuego según EN 13501-6

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Concentric conductor: bare copper wire
6 Reinforcing helix: bare copper tape
7 Separator: plastic tape
8 Sheath: FRNC/LSZH

Descripción

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit Integrity E30-E60* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor of +90˚C.

  • For use in critical fire safety infrastructure (in compliance with VKF, ASTRA, Tunnels Directive, etc.), particularly in escape routes and emergency lines.
  • Reacción al fuego (Euroclases) EN 13501-6: B2ca
  • Cero halógeno gases no corrosivos IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Propagación de llamas IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Dispersión de llamas IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C, VDE 0482-332-3-22/-24 Cat. A/C, AREI-RGIE Art.104-F2
  • Densidad de humo IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
  • Integridad del Sistema de Circuito DIN 4102-12, AREI-RGIE Art.104-FR2
  • Integridad de circuito (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), VDE 0482-362, AREI-RGIE Art.104-FR1
  • System Circuit Integrity is dependent on installation method.
  • Tensión de prueba a 50 Hz 4000 V
  • Temperatura de instalación -5 °C - +50 °C
  • Temperatura de funcionamiento -45 °C - +90 °C
  • Color de la funda exterior anaranjado
  • Integridad de circuito E30-E60*
  • Integridad del aislamiento FE 180
  • Mínimo de flexión durante la instalación (multinúcleo) 12 x D
  • Plegado mínimo durante la instalación (núcleo único) 15 x D
  • Radio de flexión mínimo permanente (multinúcleo) 12 x D
  • Radio de flexión mínimo permanente (núcleo único) 15 x D
  • Screened No

Documentos

EN DE NL FR CN ES IT
Certificado MPA file-icon Certificado MPA file-icon file-icon file-icon file-icon file-icon
CoC CoC CoC file-icon file-icon file-icon file-icon file-icon file-icon
DAT_VDEApproval_OBJ DAT_VDEApproval_OBJ file-icon file-icon file-icon file-icon file-icon file-icon
Ficha técnica Ficha técnica Ficha técnica Ficha técnica Ficha técnica file-icon Ficha técnica Ficha técnica

Versiones

N° de artículo Inventario Producto Reacción al fuegoColor de la funda exteriorNúmero de núcleosDiámetro [mm2]Diámetro exterior de la vaina [mm]Prop. CU [kg/km]Peso [kg/km]Carga de fuego [kWh/m]ConductorConstrucciónUnidad de embalajeGTIN / EAN
18694300BZ (N)HXCH FE180 E30-E60 2 x 1.5/1.5 B2ca-s1a,d1,a1 anaranjado 2 1.5/1.5 12.7 mm52 222 0.551 kWh/mde corrido LN por metro 40393910037883
18694400BZ (N)HXCH FE180 E30-E60 2 x 2.5/2.5 B2ca-s1a,d1,a1 anaranjado 2 2.5/2.5 13.5 mm80 270 0.612 kWh/mde corrido LN por metro 40393910037876
18723200BZ (N)HXCH FE180 E30-E60 2 x 4/4 B2ca-s1a,d1,a1 anaranjado 2 4/4 14.9 mm123 352 0.706 kWh/mde corrido LN por metro 40393910037296
18723400BZ (N)HXCH FE180 E30-E60 2 x 6/6 B2ca-s1a,d1,a1 anaranjado 2 6/6 16 mm182 430 0.79 kWh/mde corrido LN por metro 40393910037289
18694500BZ (N)HXCH FE180 E30-E60 3 x 1.5/1.5 B2ca-s1a,d1,a1 anaranjado 3 1.5/1.5 13.2 mm66 247 0.599 kWh/mde corrido 3L por metro 40393910037869
18694600BZ (N)HXCH FE180 E30-E60 3 x 2.5/2.5 B2ca-s1a,d1,a1 anaranjado 3 2.5/2.5 14.1 mm104 305 0.784 kWh/mde corrido 3L por metro 40393910037852
18723800BZ (N)HXCH FE180 E30-E60 3 x 16/16 B2ca-s1a,d1,a1 anaranjado 3 16/16 21.3 mm624.7 1029 1.348 kWh/mtrenzado 3L por metro 40393910037272
18723900BZ (N)HXCH FE180 E30-E60 3 x 25/16 B2ca-s1a,d1,a1 anaranjado 3 25/16 25 mm902 1435 1.799 kWh/mtrenzado 3L por metro 40393910037265
18724000BZ (N)HXCH FE180 E30-E60 3 x 35/16 B2ca-s1a,d1,a1 anaranjado 3 35/16 37.3 mm1190 1802 2.096 kWh/mtrenzado 3L por metro 40393910037258
18724100BZ (N)HXCH FE180 E30-E60 3 x 50/25 B2ca-s1a,d1,a1 anaranjado 3 50/25 31.7 mm1723 2454 2.689 kWh/mtrenzado 3L por metro 40393910037241
18724200BZ (N)HXCH FE180 E30-E60 3 x 70/35 B2ca-s1a,d1,a1 anaranjado 3 70/35 36 mm2410 3346 3.32 kWh/mtrenzado 3L por metro 40393910037234
18698500BZ (N)HXCH FE180 E30-E60 3 x 95/50 B2ca-s1a,d1,a1 anaranjado 3 95/50 41.1 mm3296 4451 4.416 kWh/mtrenzado 3L por metro 40393910037524
18698600BZ (N)HXCH FE180 E30-E60 3 x 120/70 B2ca-s1a,d1,a1 anaranjado 3 120/70 44.5 mm4236 5530 5.002 kWh/mtrenzado 3L por metro 40393910037517
18698700BZ (N)HXCH FE180 E30-E60 3 x 150/70 B2ca-s1a,d1,a1 anaranjado 3 150/70 49.2 mm5100 6737 6.114 kWh/mtrenzado 3L por metro 40393910037500
18698800BZ (N)HXCH FE180 E30-E60 3 x 240/120 B2ca-s1a,d1,a1 anaranjado 3 240/120 61.5 mm8242 10918 9.391 kWh/mtrenzado 3L por metro 40393910037494
18694700BZ (N)HXCH FE180 E30-E60 4 x 1.5/1.5 B2ca-s1a,d1,a1 anaranjado 4 1.5/1.5 14.1 mm81 282 0.677 kWh/mde corrido 3LN por metro 40393910037845
18694800BZ (N)HXCH FE180 E30-E60 4 x 2.5/2.5 B2ca-s1a,d1,a1 anaranjado 4 2.5/2.5 15.1 mm128 351 0.754 kWh/mde corrido 3LN por metro 40393910037838
18694900BZ (N)HXCH FE180 E30-E60 4 x 4/4 B2ca-s1a,d1,a1 anaranjado 4 4/4 16.7 mm200 466 0.87 kWh/mde corrido 3LN por metro 40393910037821
18695000BZ (N)HXCH FE180 E30-E60 4 x 6/6 B2ca-s1a,d1,a1 anaranjado 4 6/6 18.1 mm297 614 1.051 kWh/mde corrido 3LN por metro 40393910037814
18695100BZ (N)HXCH FE180 E30-E60 4 x 10/10 B2ca-s1a,d1,a1 anaranjado 4 10/10 20.1 mm504 860 1.25 kWh/mde corrido 3LN por metro 40393910037807
18698900BZ (N)HXCH FE180 E30-E60 4 x 16/16 B2ca-s1a,d1,a1 anaranjado 4 16/16 23.4 mm796 1247 1.494 kWh/mtrenzado 3LN por metro 40393910037487
18699000BZ (N)HXCH FE180 E30-E60 4 x 25/16 B2ca-s1a,d1,a1 anaranjado 4 25/16 27.2 mm1142 1744 2.106 kWh/mtrenzado 3LN por metro 40393910037470
18699100BZ (N)HXCH FE180 E30-E60 4 x 35/16 B2ca-s1a,d1,a1 anaranjado 4 35/16 29.8 mm1526 2199 2.432 kWh/mtrenzado 3LN por metro 40393910037463
18699200BZ (N)HXCH FE180 E30-E60 4 x 50/25 B2ca-s1a,d1,a1 anaranjado 4 50/25 34.8 mm2203 3029 3.298 kWh/mtrenzado 3LN por metro 40393910037456
18699300BZ (N)HXCH FE180 E30-E60 4 x 70/35 B2ca-s1a,d1,a1 anaranjado 4 70/35 39.5 mm3082 4132 3.968 kWh/mtrenzado 3LN por metro 40393910037449
18699400BZ (N)HXCH FE180 E30-E60 4 x 95/50 B2ca-s1a,d1,a1 anaranjado 4 95/50 45.2 mm4208 5509 5.298 kWh/mtrenzado 3LN por metro 40393910037432
18699500BZ (N)HXCH FE180 E30-E60 4 x 120/70 B2ca-s1a,d1,a1 anaranjado 4 120/70 49.1 mm5388 6870 6.051 kWh/mtrenzado 3LN por metro 40393910037425
18699600BZ (N)HXCH FE180 E30-E60 4 x 150/70 B2ca-s1a,d1,a1 anaranjado 4 150/70 54.3 mm6540 8407 6.971 kWh/mtrenzado 3LN por metro 40393910037418
18699700BZ (N)HXCH FE180 E30-E60 4 x 185/95 B2ca-s1a,d1,a1 anaranjado 4 185/95 59.8 mm8159 10480 9.075 kWh/mtrenzado 3LN por metro 40393910037401
18699800BZ (N)HXCH FE180 E30-E60 4 x 240/120 B2ca-s1a,d1,a1 anaranjado 4 240/120 67.9 mm10546 13611 11.41 kWh/mtrenzado 3LN por metro 40393910037395
18724402BZ (N)HXCH FE180 E30-E60 7 x 1.5/2.5 B2ca-s1b,d1,a1 anaranjado 7 1.5/2.5 16.1 mm133 391 0.884 kWh/mde corrido 7L por metro 40393910037227