Zurück zu: Lifthängekabel



FH Module Concept – Low Fire Hazard
Drawing according to article number 191114 - Type 8859-F




Beschreibung
Elevator suspension cable for indoor and panoramic elevators
- To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately.
- Betriebstemperatur -15 °C - +70 °C
- Mantelfarbe schwarz
- Mantelmaterial low fire hazard
- Bündeln with black sheath
- Coax schwarz
- Ader black, white numbered, G = with green-yellow core(s)
- Glasfasern orange 50 Μm, grey 62.5 Μm
- Pair/quad various colours or black with white numbers,
- Nennspannung Uo/U according to table
- Kern Flexibel class 5
- Aderisolation low fire hazard
- Unterstützende Elemente ST = Steel, diameter in [mm]
- Maximale freie Federung 220 m
- Beschleunigung 1.2 m/s²
- Maximale Fahrhöhe 400 m
- Maximale Laufgeschwindigkeit 12 m/s
- Empfohlener Schlaufendurchmesser approx. 650 mm, tolerance -50/+150 mm
- Norm für flexible Aufzugssteuerleitungen EN 50214
Dokumentation
Versionen
Artikelnr. | Bestand | Produkt | Kabelkonstruktion | Cu-Zahl [kg/km] | Gewicht [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
191114
|
8859-F | 12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ) | 698 | 1929 | 40393910069679 | |
191483
|
8866-F | 10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm | 616 | 2184 | 40393910069297 |