Zurück zu: Lifthängekabel



FM – Low Fire Hazard – supported
Drawing according to article number 185124 - Type 8696-F




Beschreibung
Elevator suspension cable for indoor and panoramic elevators.
- To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
- Betriebstemperatur -15 °C - +70 °C
- Mantelfarbe schwarz
- Mantelmaterial low fire hazard
- Coax schwarz
- Ader black, white numbered, G = with green-yellow core(s)
- Pair/quad various colours or black with white numbers
- Nennspannung Uo/U according to table
- Kern Flexibel class 5
- Aderisolation low fire hazard
- Unterstützende Elemente HTF = High tensile fibre
- Maximale freie Federung 80 m
- Beschleunigung 1.2 m/s²
- Maximale Fahrhöhe 150 m
- Maximale Laufgeschwindigkeit 6.3 m/s
- Empfohlener Schlaufendurchmesser according to table, tolerance -50/+100 mm
- Norm für flexible Aufzugssteuerleitungen EN 50214
Dokumentation
Versionen
Artikelnr. | Bestand | Produkt | Kabelkonstruktion | Cu-Zahl [kg/km] | Gewicht [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
185127
|
8622-F | 12 G 1.00 + 1 CX 75 Ω | 139 | 484 | 40393910077339 | |
185124
|
8696-F | 12 G 1.00 + 1 x 4 x 0.34 mm² (STQ) | 142 | 499 | 40393910077360 | |
191094
|