Back to: Traveling cables

FH Module Concept – Low Fire Hazard

High rise – travelling height maximum 400m

Drawing according to article number 191114 - Type 8859-F

Description

Elevator suspension cable for indoor and panoramic elevators

  • To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately.
  • Core flexible class 5
  • Core insulation low fire hazard
  • Supporting members ST = Steel, diameter in [mm]
  • Rated voltage Uo/U according to table
  • Operating temperature -15 °C - +70 °C
  • Outer sheath colour black
  • Outer sheath material low fire hazard
  • Bundle with black sheath
  • Coax black
  • Core black, white numbered, G = with green-yellow core(s)
  • Optical fibres orange 50 Μm, grey 62.5 Μm
  • Pair/quad various colours or black with white numbers,
  • Maximum free suspension 220 m
  • Acceleration 1.2 m/s²
  • Maximum running speed 12 m/s
  • Maximum travelling height 400 m
  • Recommended loop diameter approx. 650 mm, tolerance -50/+150 mm
  • Standard for flexible lift control cables EN 50214

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product Cable designCU rate [kg/km]Weight [kg/km]GTIN / EAN
191114 8859-F 12 G 2.00 + 30 x 1.00 + 7 x 2 x 0.50 (FTP) + 3 x 4 x 0.50 mm² (STQ) 698 1929 40393910069679
191483 8866-F 10 G 2.50 + 7 x 1.50 + 6 x 1.00 + 12 x 2 x 0.75 mm² (FTP) + 4 FO G50/125 µm 616 2184 40393910069297