Back to: Traveling cables



FL – Low Fire Hazard – unsupported
Low rise – travelling height maximum 80m
Drawing according to article number 191113 - Type 8582-F




Description
Elevator suspension cable for indoor and panoramic elevators.
- To comply with the correct installation procedures please refer to the Datwyler installation manual which is available separately
- Core flexible class 5
- Core insulation low fire hazard
- Supporting members none
- Rated voltage Uo/U according to table
- Operating temperature -15 °C - +70 °C
- Outer sheath colour black
- Outer sheath material low fire hazard
- Coax black
- Core black, white numbered, G = with green-yellow core(s)
- Pair/quad various colours or black with white numbers
- Maximum free suspension 45 m
- Acceleration 0.8 m/s²
- Maximum running speed 4 m/s
- Maximum travelling height 80 m
- Recommended loop diameter according to table, tolerance -50/+100 mm
- Standard for flexible lift control cables EN 50214
Documentation
Versions
Article No. | Stock | Product | Cable design | CU rate [kg/km] | Weight [kg/km] | GTIN / EAN |
---|---|---|---|---|---|---|
191110
|
8511-F | 12 G 0.75 mm² | 87 | 259 | 40393910069716 | |
185125
|
8511-F | 18 G 0.75 mm² | 130 | 382 | 40393910077353 | |
191112
|
8511-F | 24 G 0.75 mm² | 173 | 511 | 40393910069693 | |
191111
|
8636-F | 12 G 0.75 + 3 x 2 x 0.50 mm² (FTP) | 123 | 420 | 40393910069709 | |
182205
|
8827-F | 3 G 2.50 + 14 x 1.00 + 4 x 2 x 0.34 mm² (FTP) | 244 | 735 | 40393910077766 | |
191113
|
8582-F | 24 G 1.00 + 3 x 2 x 0.75 mm² (FTP) + 1 CX 75 Ω | 306 | 958 | 40393910069686 | |
190491
|
8582-F | 2 x 1.50 + 8 x 2 x 0.50 mm² (FTP) + 1 CX 75 Ω | 149 | 524 | 40393910070873 |