Back to: Safety cables

FE5-CL

Safety cable, 0.6/1kV, armoured with rodent protection, euroclass Dca
halogen-free, with improved fire characteristics,
with reference to SEV TP 20B/3C and CENELEC HD 604 S1 part 5. H

1 Conductor: solid/stranded
2 Insulation: cross-linked PE, zero halogen
3 Inner sheath: Polyolefin, flame retardant, zero halogen
4 Armouring: galvanised steel tape
5 Sheath: FRNC/LSZH

Description

For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete. Also suitable for outdoor applications.
The cable should only be laid directly in earth or water if a protective conduit is used.
Permitted operating temperature at conductor of +90°C.

  • Outer sheath material Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
  • Armouring (rodent protection) galvanised steel tape (CL)
  • Conductor Bare copper, solid or stranded, IEC 60228, EN 60228
  • Core colours CENELEC HD 308 S2
  • Inner sheath Flame retardant Polyolefin compound CENELEC HD 604 S1 part 5 sec. H
  • Insulation Cross-linked Polyethylene CENELEC HD 604 S1 part 5 sec. H
  • Test voltage at 50Hz 3500 V
  • Installation temperature -5 °C - +50 °C
  • Operating temperature -45 °C - +90 °C
  • Circuit Integrity No
  • Insulation integrity No
  • Minimum bending during installation (multi core) 12 x D
  • Minimum bending during installation (single core) 15 x D
  • Minimum bending radius permanent (multi core) 12 x D
  • Minimum bending radius permanent (single core) 15 x D
  • Additional dimensions available on request.
  • Reaction to fire (Euroclasses) EN 13501-6: Dca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame Spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
  • Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product Reaction To FireNumber of CoresDiameter mm²Outer sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]ConductorConstructionPacking unitGTIN
19621600DZ FE5-CL-J 1 x 300 Dca-s2,d1,a1 1 300 33 2976 3354 3.61 kWh/mstranded L by the metre 40393910018622
19627500DZ FE5-CL-J 2 x 1.5 Dca-s2,d1,a1 2 1.5 8 29 112 0.28 kWh/msolid LN by the metre 40393910018196
19586400DZ FE5-CL-J 2 x 2.5 Dca-s2,d1,a1 2 2.5 10 49 151 0.37 kWh/msolid LN by the metre 40393910021110
19626800DZ FE5-CL-J 3 x 1.5 Dca-s2,d1,a1 3 1.5 9 43 118 0.3 kWh/msolid LNPE by the metre 40393910018400
19273000DZ FE5-CL-J 3 x 2.5 Dca-s2,d1,a1 3 2.5 10 72 168 0.41 kWh/msolid LNPE by the metre 40393910026887
19109100DZ FE5-CL-J 3 x 4 Dca-s2,d1,a1 3 4 11 115 238 0.48 kWh/msolid LNPE by the metre 40393910031799
19156800DZ FE5-CL-J 3 x 10 Dca-s2,d1,a1 3 10 16 288 499 0.91 kWh/msolid LNPE by the metre 40393910030358
19164500DZ FE5-CL-J 3 x 6 Dca-s2,d1,a1 3 6 13 173 329 0.65 kWh/msolid LNPE by the metre 40393910030167
19167200DZ FE5-CL-J 4 x 1.5 Dca-s2,d1,a1 4 1.5 9 58 151 0.36 kWh/msolid 3LPE by the metre 40393910030013
19626100DZ FE5-CL-J 4 x 2.5 Dca-s2,d1,a1 4 2.5 11 96 214 0.48 kWh/msolid 3LPE by the metre 40393910018523
19626400DZ FE5-CL-J 5 x 1.5 Dca-s2,d1,a1 5 1.5 10 72 175 0.45 kWh/msolid 3LNPE by the metre 40393910018431
19106400DZ FE5-CL-J 5 x 2.5 Dca-s2,d1,a1 5 2.5 12 120 260 0.59 kWh/msolid 3LNPE by the metre 40393910031928
19273100DZ FE5-CL-J 5 x 4 Dca-s2,d1,a1 5 4 14 192 364 0.73 kWh/msolid 3LNPE by the metre 40393910026856
19059500DZ FE5-CL-J 5 x 6 Dca-s2,d1,a1 5 6 16 288 490 0.92 kWh/msolid 3LNPE by the metre 40393910032581
18838900DZ FE5-CL-J 5 x 10 Dca-s2,d1,a1 5 10 18 480 732 1.56 kWh/msolid 3LNPE by the metre 40393910035131
19040100DZ FE5-CL-J 5 x 16 Dca-s2,d1,a1 5 16 24 768 1120 2.03 kWh/mstranded 3LNPE by the metre 40393910032857
19106300DZ FE5-CL-J 5 x 25 Dca-s2,d1,a1 5 25 28 1200 1710 2.76 kWh/mstranded 3LNPE by the metre 40393910031966
19109000DZ FE5-CL-J 5 x 35 Dca-s2,d1,a1 5 35 31.8 1680 2277 3.44 kWh/mstranded 3LNPE by the metre 40393910031836
19103600DZ FE5-CL-J 5 x 50 Dca-s2,d1,a1 5 50 36 2400 3144 4.74 kWh/mstranded 3LNPE by the metre 40393910032048
19160000DZ FE5-CL-J 5 x 95 Dca-s2,d1,a1 5 95 49 4560 5854 8.16 kWh/mstranded 3LNPE by the metre 40393910030266
18092900DZ FE5-CL-J 7 x 6 Dca-s2,d1,a1 7 6 17 403 624 1.1 kWh/msolid 6LPE by the metre 40393910042573
18453100DZ FE5-CL-J 7 x 10 Dca-s2,d1,a1 7 10 20 672 950 1.48 kWh/msolid 6LPE by the metre 40393910040104
19628600DZ FE5-CL 1 x 35 Dca-s2,d1,a1 1 35 14 378 488 0.74 kWh/mstranded L by the metre 40393910017991