(N)HXCH FE180 E90

Safety cable, 0.6/1kV, Keram
halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E90 in accordance with DIN 4102-12

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Concentric conductor: bare copper wire
6 Reinforcing helix: bare copper tape
7 Separator: plastic tape
8 Sheath: FRNC/LSZH

Description

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of System Circuit Integrity E90* in accordance with DIN 4102-12. System Circuit Integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor of +90˚C.

  • Outer sheath colour orange
  • Outer sheath material Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 "HM4"
  • Concentric conductor Bare copper wires with reinforced helix
  • Conductor Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
  • Core colours CENELEC HD 308 S2, VDE 0293
  • Filler Halogen-free compound or plastic tape
  • Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 "HXI1"
  • Test voltage at 50Hz 4000 V
  • Installation temperature -5 °C - +50 °C
  • Operating temperature -45 °C - +90 °C
  • Minimum bending during installation (multi core) 12 x D
  • Minimum bending radius permanent (multi core) 12 x D
  • System Circuit Integrity is dependent on installation method.
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame Spread IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C, VDE 0482-332-3-22/-24 Cat. A/C, AREI-RGIE Art.104-F2
  • Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
  • System circuit integrity DIN 4102-12, VdS 3423 (Single-core more than 16.0 mm²), AREI-RGIE Art.104-FR2
  • Circuit Integrity (FE180) IEC 60331-11/-21 (180 minutes),VDE 0472-814 (FE180),BS 6387 C/W/Z,IEC 60331-1 (120 minutes),IEC 60331-2 (120 minutes),EN 50200 (PH120 minutes),VDE 0482-200 (PH120),VDE 0482-362,AREI-RGIE Art.104-FR1

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet
MPA Certificate file-icon MPA Certificate file-icon file-icon file-icon file-icon file-icon
VDE Certificate VDE Certificate file-icon file-icon file-icon file-icon file-icon file-icon
VDS Certificate file-icon VDS Certificate file-icon file-icon file-icon file-icon file-icon

Versions

Article No.StockProductNumber of CoresDiameter mm²Outer sheath diameter [mm]CU rate [kg\km]Weight [kg\km]Fire load [kWh\m]ConductorConstruction
186071 (N)HXCH FE180 E90 3 x 1.5/1.531.5/1.513.266 kg/km2490.65 kWh/msolid3L
186195 (N)HXCH FE180 E90 3 x 2.5/2.532.5/2.514.1104 kg/km3090.72 kWh/msolid3L
186197 (N)HXCH FE180 E90 3 x 4/434/415.6161 kg/km4030.84 kWh/msolid3L
187278 (N)HXCH FE180 E90 3 x 6/636/616.9240 kg/km5270.94 kWh/msolid3L
187279 (N)HXCH FE180 E90 3 x 10/10310/1018.6408 kg/km727 kg/km1.15 kWh/msolid3L
196386 (N)HXCH FE180 E90 3 x 16/16316/1624.4 mm643 kg/km11441.64 kWh/mstranded3L
187406 (N)HXCH FE180 E90 3 x 25/16325/1625.8902 kg/km1496 kg/km1.95 kWh/mstranded3L
172417 (N)HXCH FE180 E90 3 x 35/16335/16291190 kg/km19462.25 kWh/mstranded3L
187408 (N)HXCH FE180 E90 3 x 50/25350/2532.51723 kg/km25562.90 kWh/mstranded3L
187409 (N)HXCH FE180 E90 3 x 70/35370/3537.62410 kg/km35393.42 kWh/mstranded3L
187410 (N)HXCH FE180 E90 3 x 95/50395/5041.93296 kg/km46124.50 kWh/mstranded3L
187411 (N)HXCH FE180 E90 3 x 120/703120/7045.34236 kg/km57035.02 kWh/mstranded3L
187412 (N)HXCH FE180 E90 3 x 150/703150/70505100 kg/km69316.00 kWh/mstranded3L
187414 (N)HXCH FE180 E90 3 x 240/1203240/12062.48242 kg/km111839.08 kWh/mstranded3L
186072 (N)HXCH FE180 E90 4 x 1.5/1.541.5/1.514.181 kg/km2840.73 kWh/msolid3LN
186196 (N)HXCH FE180 E90 4 x 2.5/2.542.5/2.515.1128 kg/km3560.82 kWh/msolid3LN
186198 (N)HXCH FE180 E90 4 x 4/444/416.7200 kg/km4670.96 kWh/msolid3LN
186199 (N)HXCH FE180 E90 4 x 6/646/618.1297 kg/km6251.13 kWh/msolid3LN
186200 (N)HXCH FE180 E90 4 x 10/10410/1020.1504 kg/km8681.33 kWh/msolid3LN
186131 (N)HXCH FE180 E90 4 x 16/16416/1625.3796 kg/km14001.81 kWh/mstranded3LN
186132 (N)HXCH FE180 E90 4 x 25/16425/1628.91142 kg/km18982.28 kWh/mstranded3LN
186133 (N)HXCH FE180 E90 4 x 35/16435/1631.61526 kg/km23802.60 kWh/mstranded3LN
186134 (N)HXCH FE180 E90 4 x 50/25450/2536.72203 kg/km32473.49 kWh/mstranded3LN
186135 (N)HXCH FE180 E90 4 x 70/35470/3541.33082 kg/km43754.25 kWh/mstranded3LN
186136 (N)HXCH FE180 E90 4 x 95/50495/5046.44208 kg/km57465.53 kWh/mstranded3LN
186137 (N)HXCH FE180 E90 4 x 120/704120/7050.15388 kg/km70946.25 kWh/mstranded3LN
186138 (N)HXCH FE180 E90 4 x 150/704150/7055.36540 kg/km86517.58 kWh/mstranded3LN
186139 (N)HXCH FE180 E90 4 x 185/954185/9560.88159 kg/km107519.18 kWh/mstranded3LN
186140 (N)HXCH FE180 E90 4 x 240/1204240/12069.210546 kg/km1398011.60 kWh/mstranded3LN
186073 (N)HXCH FE180 E90 7 x 1.5/2.571.5/2.516.1133 kg/km3940.94 kWh/msolid7L
191096 (N)HXCH FE180 E90 7 x 2.5/2.572.5/2.517.3200 kg/km4871.05 kWh/msolid7L
187415 (N)HXCH FE180 E90 12 x 1.5/2.5121.5/2.520.2205.8 kg/km5971.38 kWh/msolid12L
187402 (N)HXCH FE180 E90 24 x 1.5/6241.5/627413 kg/km10782.32 kWh/msolid24L
187403 (N)HXCH FE180 E90 24 x 2.5/10242.5/1029.6696 kg/km14262.69 kWh/msolid24L
187404 (N)HXCH FE180 E90 30 x 1.5/6301.5/628.4499 kg/km12502.67 kWh/msolid30L
Additional dimensions available on request.