Back to: Safety cables

(N)HXH CL FE180 E30-E60

Safety cable, 0.6/1kV armoured with rodent protection, Keram
halogen-free, with improved fire characteristics,
with reference to VDE 0266 and CENELEC HD 604 S1,
circuit integrity (FE180) in accordance with VDE 0472-814, IEC 60331,
System Circuit Integrity E30-E60* in accordance with DIN 4102-12

1 Conductor: solid/stranded
2 Fire barrier: high-peformance Keram compound
3 Insulation: cross-linked polymer, zero halogen
4 Filler: flame retardant, zero halogen
5 Inner sheath: Polyolefin, flame retardant, low smoke, zero halogen
6 Armouring: galvanised steel tape
7 Sheath: FRNC/LSZH

Description

Cables with intrinsic fire resistance are installed in all areas that require special protection of people and equipment against fire and fire damages and where strict security requirements must be fulfilled. Suitable for indoor applications. For outdoor applications, protection must be provided against exposure to direct sunlight. The cable should only be laid directly in earth or water if a protective conduit is used. These cables correspond to the demands of Circuit Integrity E30-E60* in accordance with DIN 4102-12. Circuit Integrity is guaranteed at an operating voltage up to 400V.
Permitted operating temperature at conductor of +90˚C.

  • Outer sheath material Flame retardant Polyolefin compound, CENELEC HD 604 S1 and VDE 0276-604 "HM4"
  • Armouring (rodent protection) Single-core cable with copper tape (CLCU) and multicore cable with galvanised steel tape (CL)
  • Conductor Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
  • Core colours CENELEC HD 308 S2, VDE 0293
  • Filler Flame retardant, halogen-free thermoplastic compound
  • Inner sheath Flame retardant Polyolefin compound,CENELEC HD 604 S1 and VDE 0276-604 "HM4"
  • Insulation Double insulation, cross-linked, high-performance Keram special compound, VDE 0266 "HXI1"
  • Test voltage at 50Hz 4000 V
  • Installation temperature -5 °C - +50 °C
  • Operating temperature -45 °C - +90 °C
  • Circuit Integrity E30-E60*
  • Insulation integrity FE 180
  • Minimum bending during installation (multi core) 12 x D
  • Minimum bending during installation (single core) 15 x D
  • Minimum bending radius permanent (multi core) 12 x D
  • Minimum bending radius permanent (single core) 15 x D
  • System Circuit Integrity is dependent on installation method.
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame Spread IEC 60332-3-22/-24 Cat. A/C, EN 60332-3-22/-24 Cat. A/C, VDE 0482-332-3-22/-24 Cat. A/C, AREI-RGIE Art.104-F2
  • Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
  • System circuit integrity DIN 4102-12, AREI-RGIE Art.104-FR2
  • Circuit Integrity (FE180) IEC 60331-11/-21 (180 minutes), VDE 0472-814 (FE180), BS 6387 C/W/Z, IEC 60331-1 (120 minutes), IEC 60331-2 (120 minutes), EN 50200 (PH120 minutes), VDE 0482-200 (PH120), VDE 0482-362, AREI-RGIE Art.104-FR1

Documentation

ENDENLFRCNESITAT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet Datasheet

Versions

Article No.StockProductCU rate (AT)Number of CoresDiameter mm²Outer sheath diameter [mm]Weight [kg/km]Fire load [kWh/m]ConductorConstruction
192350 (N)HXH-O CL FE180 E30-E60 2 x 1.530 kg/km21.514.93330.94 kWh/msolidLN
187562 (N)HXH-O CL FE180 E30-E60 2 x 2.550 kg/km22.5163801.02 kWh/msolidLN
191612 (N)HXH-O CL FE180 E30-E60 2 x 480 kg/km24174501.13 kWh/msolidLN
187563 (N)HXH-O CL FE180 E30-E60 2 x 6120 kg/km26185311.25 kWh/msolidLN
191107 (N)HXH-J CL FE180 E30-E60 3 x 1.545 kg/km31.5163611.00 kWh/msolidLNPE
186940 (N)HXH-J CL FE180 E30-E60 3 x 2.575 kg/km32.516.34221.10 kWh/msolidLNPE
192351 (N)HXH-J CL FE180 E30-E60 3 x 4120 kg/km34185091.22 kWh/msolidLNPE
188326 (N)HXH-J CL FE180 E30-E60 3 x 6180 kg/km36196071.35 kWh/msolidLNPE
191597 (N)HXH-J CL FE180 E30-E60 3 x 10300 kg/km310217851.54 kWh/msolidLNPE
188327 (N)HXH-J CL FE180 E30-E60 3 x 16480 kg/km3162410741.93 kWh/mstrandedLNPE
190590 (N)HXH-J CL FE180 E30-E60 4 x 2.5100 kg/km42.5184751.22 kWh/msolid3LPE
191102 (N)HXH-J CL FE180 E30-E60 4 x 4160 kg/km44195851.36 kWh/msolid3LPE
192593 (N)HXH-J CL FE180 E30-E60 4 x 6230 kg/km46207091.51 kWh/msolid3LPE
192594 (N)HXH-J CL FE180 E30-E60 4 x 10384 kg/km410229401.76 kWh/msolid3LPE
186980 (N)HXH-J CL FE180 E30-E60 4 x 16640 kg/km4162512932.20 kWh/mstranded3LPE
186981 (N)HXH-J CL FE180 E30-E60 4 x 251000 kg/km4252918142.78 kWh/mstranded3LPE
186982 (N)HXH-J CL FE180 E30-E60 4 x 351400 kg/km4353222963.16 kWh/mstranded3LPE
190589 (N)HXH-J CL FE180 E30-E60 4 x 502000 kg/km4503630304.02 kWh/mstranded2LNPE
192428 (N)HXH-J CL FE180 E30-E60 4 x 702800 kg/km4704040155.05 kWh/mstranded3LPE
192429 (N)HXH-J CL FE180 E30-E60 4 x 953800 kg/km4954653436.52 kWh/mstranded3LPE
192430 (N)HXH-J CL FE180 E30-E60 4 x 1204800 kg/km41204964337.26 kWh/mstranded3LPE
192347 (N)HXH-J CL FE180 E30-E60 5 x 1.575 kg/km51.5184631.25 kWh/msolid3LNPE
188117 (N)HXH-J CL FE180 E30-E60 5 x 2.5125 kg/km52.5195451.38 kWh/msolid3LNPE
188118 (N)HXH-J CL FE180 E30-E60 5 x 4200 kg/km54206751.54 kWh/msolid3LNPE
186941 (N)HXH-J CL FE180 E30-E60 5 x 6300 kg/km56218251.72 kWh/msolid3LNPE
186942 (N)HXH-J CL FE180 E30-E60 5 x 10500 kg/km5102410951.98 kWh/msolid3LNPE
187154 (N)HXH-J CL FE180 E30-E60 5 x 16800 kg/km5162714522.53 kWh/mstranded3LNPE
190525 (N)HXH-J CL FE180 E30-E60 5 x 16800 kg/km5162615312.53 kWh/mstranded3LNPE
186984 (N)HXH-J CL FE180 E30-E60 5 x 251250 kg/km5253121683.23 kWh/mstranded3LNPE
187132 (N)HXH-J CL FE180 E30-E60 5 x 351680 kg/km5353527023.85 kWh/mstranded3LNPE
190529 (N)HXH-J CL FE180 E30-E60 5 x 351750 kg/km5353528013.85 kWh/mstranded3LNPE
187131 (N)HXH-J CL FE180 E30-E60 5 x 502500 kg/km5503936134.83 kWh/mstranded3LNPE
191565 (N)HXH-J CL FE180 E30-E60 5 x 502500 kg/km5503936784.83 kWh/mstranded3LNPE
194049 (N)HXH-J CL FE180 E30-E60 5 x 703360 kg/km5704549996.05 kWh/mstranded3LNPE
188094 (N)HXH-J CL FE180 E30-E60 6 x 4240 kg/km64206931.74 kWh/msolid5LPE
185232 (N)HXH-J CL FE180 E30-E60 7 x 1.5105 kg/km71.5195291.38 kWh/msolid6LPE
185245 (N)HXH-J CL FE180 E30-E60 7 x 4280 kg/km74217971.71 kWh/msolid6LPE
185247 (N)HXH-J CL FE180 E30-E60 7 x 6420 kg/km76239851.9 kWh/msolid6LPE
185248 (N)HXH-J CL FE180 E30-E60 7 x 10700 kg/km7102513402.2 kWh/msolid6LPE
188095 (N)HXH-J CL FE180 E30-E60 8 x 4320 kg/km84238341.91 kWh/msolid7LPE
185239 (N)HXH-J CL FE180 E30-E60 12 x 2.5300 kg/km122.5239422.13 kWh/msolidLPE
185233 (N)HXH-J CL FE180 E30-E60 16 x 1.5240 kg/km161.5249222.24 kWh/msolid15LPE
192725 (N)HXH-J CL FE180 E30-E60 16 x 2.5384 kg/km162.52611382.52 kWh/msolid15LPE
196400 (N)HXH-J CL FE180 E30-E60 16 x 416427.5 mm1414solid15LPE
185235 (N)HXH-J CL FE180 E30-E60 30 x 1.5450 kg/km301.53014023.25 kWh/msolid29LPE
185241 (N)HXH-J CL FE180 E30-E60 30 x 2.5750 kg/km302.53318263.81 kWh/msolid29LPE
Additional dimensions available on request.