Back to: Safety cables

J-H(St)H...Bd fire alarm

Fire alarm cable, max. 300V
halogen-free, with improved fire characteristics,
VDE 0815

1 Conductor: solid
2 Insulatio: halogen-free polymer compound
3 Separator: plastic tape
4 Drain wire: tinned copper
5 Shielding: Al-laminated plastic foil
6 Sheath: FRNC/LSZH

Description

Installation cable with electrostatic shield for areas vulnerable to fire and with high concentration of people and property value. For ICT systems for lossless data and signal transmission. Suitable for laying in dry and humid rooms, on-wall and in-wall, also for outdoor use.
No underground laying. Not to be used for high-voltage transmission.
Permitted operating temperature at conductor of +70°C.

  • Conductor Bare copper, solid, 0.6 or 0.8 mm diameter
  • Core colours DIN VDE 0815
  • Insulation Halogen-free polymer compound, EN 50290-2-26
  • Shielding Al-laminated plastic foil with drain wire, copper tinned
  • Stranding Cores twisted to star-quads and quads to units
  • Capacitive coupling 0,6 mm, 100m @ 800Hz 300 pF/km
  • Capacitive coupling 0,8 mm, 100m @ 800Hz 200 pF/km
  • Maximum loop resistance 0,6 mm 130 Ω/km
  • Maximum loop resistance 0,8 mm 73.2 Ω/km
  • Minimum insulation resistance 100 MΩ x km
  • operating capacity, 1km @ 800Hz 120 nF/km
  • peak voltage 300 V
  • Test voltage 50Hz, core/core 800 V
  • Test voltage 50Hz, core/screen 800 V
  • Installation temperature -5 °C - +50 °C
  • Operating temperature -30 °C - +70 °C
  • Outer sheath material Halogen-free polymer compound, EN 50290-2-27
  • Circuit Integrity No
  • Insulation integrity No
  • Minimum bending during installation (multi core) 7.5 x D
  • Minimum bending radius permanent (multi core) 2.5 x D
  • Additional dimensions available on request.
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
  • Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product Outer sheath colourNumber of pairsNumber of CoresDiameter mmOuter sheath diameter [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Packing unitGTIN / EAN
157892 J-H(St)H...Bd fire alarm 2x2x0.8 mm red 2 2 0.8 mm6.5 25 59 0.16 kWh/mby the metre 40393910207637
157893 J-H(St)H...Bd fire alarm 4x2x0.8 mm red 4 2 0.8 mm8.5 45 111 0.29 kWh/mby the metre 40393910207620
157894 J-H(St)H...Bd fire alarm 6x2x0.8 mm red 6 2 0.8 mm10.5 65 132 0.35 kWh/mby the metre 40393910207613
157895 J-H(St)H...Bd fire alarm 10x2x0.8 mm red 10 2 0.8 mm13 106 216 0.55 kWh/mby the metre 40393910207606
1172017 J-H(St)H...Bd fire alarm 20x2x0.8 mm red 20 2 0.8 mm15.5 206 508 1.21 kWh/mby the metre 40393910107104
1172018 J-H(St)H...Bd fire alarm 30x2x0.8 mm red 30 2 0.8 mm16.3 307 599 1.36 kWh/mby the metre 40393910107098
1172019 J-H(St)H...Bd fire alarm 40x2x0.8 mm red 40 2 0.8 mm16.5 407 787 1.67 kWh/mby the metre 40393910107081
1172021 J-H(St)H...Bd fire alarm 80x2x0.8 mm red 80 2 0.8 mm31.5 809 1476 3.18 kWh/mby the metre 40393910107074
1172022 J-H(St)H...Bd fire alarm 100x2x0.8 mm red 100 2 0.8 mm38 1010 1805 4.07 kWh/mby the metre 40393910107067