Back to: Safety cables





(N)HXM(St)H
Shielded power cable, 300/500V
halogen-free, with improved fire characteristics,
VDE 0250-214
1 Conductor: solid/stranded
2 Insulation: cross-linked PE, zero halogen
3 Drain wire: tinned copper
4 Filler: flame retardant, zero halogen
5 Shielding: Al-laminated tape
6 Sheath: FRNC/LSZH






Description
For permanent installation in dry, damp or wet areas, on or behind plasterwork or in walls or concrete, except for direct embedding in cast, rammed or vibrated concrete.
Also suitable for outdoor applications.
Permitted operating temperature at conductor of +70˚C.
- Outer sheath material Polyolefin compound, VDE 0250-214 "HM2"
- Conductor Bare copper, solid or stranded, IEC 60228 and EN 60228 (VDE 0295)
- Core colours CENELEC HD 308 S2, VDE 0293
- Filler Halogen-free compound
- Insulation Cross-linked Polyethylene, CENELEC HD 604 S1 and VDE 0276-604 "2XI1"
- Shielding Al-laminated tape with tinned copper drain wire
- Installation temperature 5 °C - +50 °C
- Operating temperature -40 °C - +90 °C
- Circuit Integrity No
- Imprint On request
- Insulation integrity No
- Minimum bending during installation (multi core) 6 x D
- Minimum bending radius permanent (multi core) 4 x D
- Additional dimensions available on request.
- Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
- Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
- Flame Spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
- Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
Documentation
Versions
Article No. | Stock | Product | Number of Cores | Diameter mm² | Outer sheath diameter [mm] | CU rate [kg/km] | Weight [kg/km] | Fire load [kWh/m] | Conductor | Construction | GTIN |
---|---|---|---|---|---|---|---|---|---|---|---|
1301193
|
(N)HXM(St)H-J 3 x 1.5/1.5 | 3 | 1.5/1.5 | 9 | 43 | 150 | 0.36 kWh/m | solid | LNPE | 40393910106428 | |
1301194
|
(N)HXM(St)H-J 3 x 2.5 | 3 | 2.5 | 10 | 72 | 150 | 0.42 kWh/m | solid | LNPE | 40393910106411 | |
1301212
|
(N)HXM(St)H-J 4 x 1.5/1.5 | 4 | 1.5/1.5 | 10 | 58 | 176 | 0.41 kWh/m | solid | 2LNPE | 40393910106381 | |
1301213
|
(N)HXM(St)H-J 4 x 2.5/2.5 | 4 | 2.5/2.5 | 11 | 96 | 245 | 0.48 kWh/m | solid | 2LNPE | 40393910106374 | |
1301214
|
(N)HXM(St)H-J 5 x 1.5 | 5 | 1.5 | 11 | 72 | 222 | 0.48 kWh/m | solid | 3LNPE | 40393910106367 | |
1301195
|
(N)HXM(St)H-J 5 x 2.5 | 5 | 2.5 | 12 | 120 | 150 | 0.56 kWh/m | solid | 3LNPE | 40393910106404 |