Back to: Trunks
DCS trunk cable, LCDU/PC - LCDU/PC, E9/125 G.652.D BLO
for interconnecting DCS breakout modules
DCS trunk cable, 6x LCDU/PC, G.652.D BLO
Description
Compact, metal-free cable construction with FR/LS0H cable sheath and 12 to 96 fibres.
Sticker labelling at both cable ends.
The length of individual cables (“legs”) may be defined on the basis of a specific project (standard 0.75 m).
The leg separation is effected with a divider housing.
All individual cables are assembled using LCDU Intelli-Cross® Pro.
Standard polarities are A to A or A to B.
The cables are fitted at both ends with protective sleeves.
-
OS2 LCDU-on-LCDU trunk cables are suitable for all high-performance applications with duplex and parallel optic signals in a data centre environment.
They are particularly used when installation requires sturdy, metal-free indoor cables that provide enhanced crush resistance and rodent protection.
For duplex applications, the pre-assempled connectors at either end of the cable are connected to the DCS modules.
The DCS trunk cables are assembled to a very high quality and guarantee optimum values for optical performance (IL/RL).
- Outer sheath colour yellow
- Outer sheath material FR/LSZH
- Cable raw material FO Indoor ZGGFR/SZGGFR / J-B(ZN)BH, B2ca
- Housing colour connector A blue
- Housing colour connector B blue
- Fibre type E9/125 G.652.D BLO
- Colour code IEC 60304
- Connector type side A LCDU/PC
- Ferrule polishing connector A PC 0°
- IL maximal, connector A 0.25 dB
- IL typical, connector A 0.1 dB
- RL minimal, connector A 50 dB
- RL typical, connector A 55 dB
- Connector type side B LCDU/PC
- Ferrule polishing connector B PC 0°
- IL maximal, connector B 0.25 dB
- IL typical, connector B 0.1 dB
- RL minimal, connector B 50 dB
- RL typical, connector B 55 dB
- Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
- Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
- Flame spread IEC 60332-3-24
- Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Documentation
Versions
Article No. | Stock | Product | Outer sheath colour | Number of fibres | Fibre type | Outer sheath material | Outer sheath diameter [mm] | Polarity | Number of connectors side A | Number of connectors side B | Number of fibres per connector A | Number of fibres per connector B | Gradation | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
47406100ZY
|
DCS trunk cable 6x LCDU/PC - 6x LCDU/PC | yellow | 12 | E9/125 G.652.D BLO | FR/LSZH | 5.9 | A to A | 6 | 6 | 2 | 2 | graduated length | by the metre | 40393910006704 | |
47406300ZY
|
DCS trunk cable 12x LCDU/PC - 12x LCDU/PC | yellow | 24 | E9/125 G.652.D BLO | FR/LSZH | 9.9 | A to A | 12 | 12 | 2 | 2 | graduated length | by the metre | 40393910006681 | |
47406500ZY
|
DCS trunk cable 24x LCDU/PC - 24x LCDU/PC | yellow | 48 | E9/125 G.652.D BLO | FR/LSZH | 9.9 | A to A | 24 | 24 | 2 | 2 | graduated length | by the metre | 40393910006667 | |
47406700ZY
|
DCS trunk cable 48x LCDU/PC - 48x LCDU/PC | yellow | 96 | E9/125 G.652.D BLO | FR/LSZH | 12.9 | A to A | 48 | 48 | 2 | 2 | graduated length | by the metre | 40393910209198 | |
47409100ZY
|
DCS trunk cable 6x LCDU/PC - 6x LCDU/PC | yellow | 12 | E9/125 G.652.D BLO | FR/LSZH | 5.9 | A to B | 6 | 6 | 2 | 2 | graduated length | by the metre | 40393910006643 | |
47409300ZY
|
DCS trunk cable 12x LCDU/PC - 12x LCDU/PC | yellow | 24 | E9/125 G.652.D BLO | FR/LSZH | 9.9 | A to B | 12 | 12 | 2 | 2 | graduated length | by the metre | 40393910006629 | |
47409500ZY
|
DCS trunk cable 24x LCDU/PC - 24x LCDU/PC | yellow | 48 | E9/125 G.652.D BLO | FR/LSZH | 9.9 | A to B | 24 | 24 | 2 | 2 | graduated length | by the metre | 40393910006605 | |
47409700ZY
|
DCS trunk cable 48x LCDU/PC - 48x LCDU/PC | yellow | 96 | E9/125 G.652.D BLO | FR/LSZH | 12.9 | A to B | 48 | 48 | 2 | 2 | graduated length | by the metre | 40393910209174 |
Intelli-Cross® is a registered trademark of SEIKOH GIKEN Co., Ltd.