DCS trunk cable, LCDU/PC - LCDU/PC, E9/125 G.652.D BLO
for interconnecting DCS breakout modules
DCS trunk cable, 6x LCDU/PC, G.652.D BLO
Description
Compact, metal-free cable construction with FR/LS0H cable sheath and 12 to 96 fibres.
OS2 versions with Euroclass Dca are available (Euroclass Cca or B2ca version available on request).
Sticker labelling at both cable ends.
The length of individual cables (“legs”) may be defined on the basis of a specific project (standard 0.75 m).
The leg separation is effected with a divider housing.
All individual cables are assembled using LCDU Intelli-Cross® Pro.
Standard polarities are A to A or A to B.
The cables are fitted at both ends with protective sleeves.
-
OS2 LCDU-on-LCDU trunk cables are suitable for all high-performance applications with duplex and parallel optic signals in a data centre environment.
They are particularly used when installation requires sturdy, metal-free indoor cables that provide enhanced crush resistance and rodent protection.
For duplex applications, the pre-assempled connectors at either end of the cable are connected to the DCS modules.
The DCS trunk cables are assembled to a very high quality and guarantee optimum values for optical performance (IL/RL).
- Outer sheath colour yellow
- Outer sheath material FR/LSZH
- Housing colour connector A blue
- Housing colour connector B blue
- Fibre type E9/125 G.652.D BLO
- Colour code IEC 60304
- Connector type side A LCDU/PC
- Ferrule polishing connector A PC 0°
- IL maximal, connector A 0.25 dB
- IL typical, connector A 0.1 dB
- RL minimal, connector A 50 dB
- RL typical, connector A 55 dB
- Connector type side B LCDU/PC
- Ferrule polishing connector B PC 0°
- IL maximal, connector B 0.25 dB
- IL typical, connector B 0.1 dB
- RL minimal, connector B 50 dB
- RL typical, connector B 55 dB
- Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
- Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
- Flame spread IEC 60332-3-24
- Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
Documentation
Versions
Article No. | Stock | Product | Outer sheath colour | Number of fibres | Fibre type | Outer sheath material | Outer sheath diameter [mm] | Polarity | Number of connectors side A | Number of connectors side B | Number of fibres per connector A | Number of fibres per connector B | Gradation | Packing unit | GTIN / EAN |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
47406100ZY
|
DCS trunk cable 6x LCDU/PC - 6x LCDU/PC | yellow | 12 | E9/125 G.652.D BLO | FR/LSZH | 5.9 mm | A to A | 6 | 6 | 2 | 2 | graduated length | by the metre | 40393910006704 | |
47406300ZY
|
DCS trunk cable 12x LCDU/PC - 12x LCDU/PC | yellow | 24 | E9/125 G.652.D BLO | FR/LSZH | 9.9 mm | A to A | 12 | 12 | 2 | 2 | graduated length | by the metre | 40393910006681 | |
47406500ZY
|
DCS trunk cable 24x LCDU/PC - 24x LCDU/PC | yellow | 48 | E9/125 G.652.D BLO | FR/LSZH | 9.9 mm | A to A | 24 | 24 | 2 | 2 | graduated length | by the metre | 40393910006667 | |
47406700ZY
|
DCS trunk cable 48x LCDU/PC - 48x LCDU/PC | yellow | 96 | E9/125 G.652.D BLO | FR/LSZH | 12.9 mm | A to A | 48 | 48 | 2 | 2 | graduated length | by the metre | 40393910209198 | |
47409100ZY
|
DCS trunk cable 6x LCDU/PC - 6x LCDU/PC | yellow | 12 | E9/125 G.652.D BLO | FR/LSZH | 5.9 mm | A to B | 6 | 6 | 2 | 2 | graduated length | by the metre | 40393910006643 | |
47409300ZY
|
DCS trunk cable 12x LCDU/PC - 12x LCDU/PC | yellow | 24 | E9/125 G.652.D BLO | FR/LSZH | 9.9 mm | A to B | 12 | 12 | 2 | 2 | graduated length | by the metre | 40393910006629 | |
47409500ZY
|
DCS trunk cable 24x LCDU/PC - 24x LCDU/PC | yellow | 48 | E9/125 G.652.D BLO | FR/LSZH | 9.9 mm | A to B | 24 | 24 | 2 | 2 | graduated length | by the metre | 40393910006605 | |
47409700ZY
|
DCS trunk cable 48x LCDU/PC - 48x LCDU/PC | yellow | 96 | E9/125 G.652.D BLO | FR/LSZH | 12.9 mm | A to B | 48 | 48 | 2 | 2 | graduated length | by the metre | 40393910209174 |