Back to: Outdoor cable

FO Outdoor wbKT Micro / A-DQ(ZN)2Y

Micro, up to 144 fibres, Euroclass Fca
metal-free, non-armoured,
dry interstices, longitudinally watertight

1 ≤ 24 fibres
2 Loose tube
3 Aramid yarn
4 HDPE sheath

Description

Very compact, metal-free fibre optic outdoor cable with up to 144 fibres in stranded loose tubes.
Easily cut-back, installation friendly cable construction with dry interstices.

  • FTTx, Fibre-to-the-home networks.
    Optimised for injection into microducts
  • Outer sheath material HDPE
  • Armouring (rodent protection) non-armoured
  • Installation temperature -5 °C - +50 °C
  • Storage temperature -40 °C - +70 °C
  • Operating temperature -40 °C - +70 °C
  • Field of application Outdoor
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Maximum number of fibres 144
  • Datwyler recommends blowing in micro and mini cables in an ambient temperature range from -2°C to +35°C.For installation, a blow-in device with a rubber pull-in bead is recommended.
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet
Tender text file-icon Tender text file-icon file-icon file-icon file-icon file-icon

Versions

Article No.StockProductReaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EANFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19170600FZ FO Outdoor Micro 1x12Fcablack12E9/125 G.652.D BLO6.6 mm150 mm35100016006000.247 kWh/mby the metre40393910029888OS21251
19008000FZ FO Outdoor Micro 2x12Fcablack24E9/125 G.652.D BLO6.6 mm150 mm35100016006000.247 kWh/mby the metre40393910033755OS21252
19022900FZ FO Outdoor Micro 3x12Fcablack36E9/125 G.652.D BLO6.6 mm150 mm35100016006000.247 kWh/mby the metre40393910033182OS21253
19023000FZ FO Outdoor Micro 4x12Fcablack48E9/125 G.652.D BLO6.6 mm150 mm35100016006000.247 kWh/mby the metre40393910033175OS21254
19023100FZ FO Outdoor Micro 5x12Fcablack60E9/125 G.652.D BLO6.6 mm150 mm35100016006000.247 kWh/mby the metre40393910033168OS21255
19023200FZ FO Outdoor Micro 6x12Fcablack72E9/125 G.652.D BLO6.5 mm150 mm40100016006000.234 kWh/mby the metre40393910033151OS21266
19181300FZ FO Outdoor Micro 8x12Fcablack96E9/125 G.652.D BLO7.6 mm250 mm55250014006000.303 kWh/mby the metre40393910029758OS21288
19181400FZ FO Outdoor Micro 6x24Fcablack144E9/125 G.652.D BLO8.2 mm250 mm58250014006000.344 kWh/mby the metre40393910029741OS22466