Back to: Outdoor cable

FO Outdoor ZwbKWT BL / A-DQ(ZN)(SR)2Y

Basic Line Euroclass Fca
central loose tube, longitudinally watertight,
corrugated steel tape, rodent proof

1 ≤ 24 fibres
2 Loose tube
3 Swelling tape
4 Aramid yarn
5 Ripcord
6 Corrugated steel tape
7 HDPE sheath

Description

Fibre optic outdoor cable with corrugated steel tape for optimal rodent protection.
Central loose tube, up to 24 fibres.
Dry construction.
Stable laying characteristics, easy installation in ducts.

  • Installation in thermoplastic ducts.
    Suitable for laying in cable platforms, cable shafts and even in complex cable trays,
    particularly where a reliable rodent protection is required.
    Direct burial.
  • Outer sheath material HDPE
  • Armouring (rodent protection) rodent proof
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -40 °C - +70 °C
  • Operating temperature -40 °C - +70 °C
  • Field of application Outdoor
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Maximum number of fibres 24
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Fca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product Reaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EANFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19020000FZ FO Outdoor BL 1x4 Fca black 4 E9/125 G.652.D OS2 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910033403 OS2 4 1 1
19609800FZ FO Outdoor BL 1x4 Fca black 4 G50/125 OM3 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910019902 OM3 4 1 1
18737700FZ FO Outdoor BL 1x6 Fca black 6 E9/125 G.652.D OS2 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910037005 OS2 6 1 1
18738900FZ FO Outdoor BL 1x6 Fca black 6 G50/125 OM3 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910036985 OM3 6 1 1
19020100FZ FO Outdoor BL 1x8 Fca black 8 E9/125 G.652.D OS2 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910033397 OS2 8 1 1
19007200FZ FO Outdoor BL 1x8 Fca black 8 G50/125 OM3 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910033779 OM3 8 1 1
19020200FZ FO Outdoor BL 1x12 Fca black 12 E9/125 G.652.D OS2 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910033380 OS2 12 1 1
19180600FZ FO Outdoor BL 1x12 Fca black 12 G50/125 OM3 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910029796 OM3 12 1 1
19268900FZ FO Outdoor BL 1x12 Fca black 12 G50/125 OM4 8.2 mm120 mm68 1000 4000 1500 0.603 kWh/mby the metre 40393910027037 OM4 12 1 1
19004000FZ FO Outdoor BL 1x16 Fca black 16 G50/125 OM3 8.2 mm120 mm84 1000 4000 1500 0.629 kWh/mby the metre 40393910033847 OM3 16 1 1
19035500FZ FO Outdoor BL 1x24 Fca black 24 E9/125 G.652.D OS2 8.2 mm120 mm84 1000 4000 1500 0.629 kWh/mby the metre 40393910033014 OS2 24 1 1
19611400FZ FO Outdoor BL 1x24 Fca black 24 G50/125 OM4 8.2 mm120 mm74 1000 4000 1500 0.629 kWh/mby the metre 40393910019810 OM4 24 1 1