Back to: Outdoor cable





FO Outdoor ZGGT BL / A-DQ(ZN)B2Y
Basic Line Euroclass Fca
central loose tube, metal-free,
longitudinally watertight, rodent protection
1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 HDPE sheath






Description
Metal-free fibre optic outdoor cable with central loose tube, up to 24 fibres.
For the use in cable ducts and for all applications with low mechanical stress (low tensile force, for example).
Non-metallic rodent protection.
-
For pulling in or blowing through ducts.
Suitable for laying in cable platforms and cable shafts/trays.
Direct burial.
- Armouring (rodent protection) rodent protected
- Installation temperature -10 °C - +50 °C
- Storage temperature -25 °C - +70 °C
- Operating temperature -25 °C - +70 °C
- Outer sheath material HDPE
- Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
- Field of application Outdoor
- Maximum number of fibres 24
- Tensile performance IEC 60794-1-21 E1
- Crush resistance IEC 60794-1-21 E3
- Impact IEC 60794-1-21 E4
- Repeated bending IEC 60794-1-21 E6
- Torsion IEC 60794-1-21 E7
- Bend IEC 60794-1-21 E11
- Temperature cycling IEC 60794-1-22 F1
- Water penetration IEC 60794-1-22 F5
- Reaction to fire (Euroclasses) EN 13501-6: Fca
- Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
Documentation
Versions
Article No. | Stock | Product | Reaction to fire | Outer sheath colour | Number of fibres | Fibre type | Outer sheath diameter [mm] | Bending radius [mm] | Weight [kg/km] | Tensile load [N] | Crush resistance short term [N] | Crush resistance continuous [N] | Fire load [kWh/m] | Packing unit | GTIN / EAN | Fibre category | Fibres per loose tube | Loose tube construction | Number of used loose tubes |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
19613400FZ
|
FO Outdoor BL 1x2 | Fca | black | 2 | E9/125 G.652.D OS2 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910019704 | OS2 | 2 | 1 | 1 | |
19129200FZ
|
FO Outdoor BL 1x4 | Fca | black | 4 | E9/125 G.652.D OS2 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910031287 | OS2 | 4 | 1 | 1 | |
19125600FZ
|
FO Outdoor BL 1x6 | Fca | black | 6 | E9/125 G.652.D OS2 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910031430 | OS2 | 6 | 1 | 1 | |
19118800FZ
|
FO Outdoor BL 1x6 | Fca | black | 6 | G50/125 OM3 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910031645 | OM3 | 6 | 1 | 1 | |
18650000FZ
|
FO Outdoor BL 1x8 | Fca | black | 8 | E9/125 G.652.D OS2 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910038798 | OS2 | 8 | 1 | 1 | |
19019200FZ
|
FO Outdoor BL 1x12 | Fca | black | 12 | E9/125 G.652.D OS2 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910033441 | OS2 | 12 | 1 | 1 | |
19119000FZ
|
FO Outdoor BL 1x12 | Fca | black | 12 | G50/125 OM3 | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910031638 | OM3 | 12 | 1 | 1 | |
19019300FZ
|
FO Outdoor BL 1x24 | Fca | black | 24 | E9/125 G.652.D OS2 | 8 | 120 | 56 | 1000 | 5000 | 2000 | 0.491 kWh/m | by the metre | 40393910033434 | OS2 | 24 | 1 | 1 | |
19262600FZ
|
FO Outdoor BL 1x12 | Fca | black | 12 | E9/125 G.652.D BLO | 7.3 | 110 | 48 | 1000 | 5000 | 2000 | 0.418 kWh/m | by the metre | 40393910027235 | OS2 | 12 | 1 | 1 |