Back to: Universal cable

FO Universal DLTS wbGGFR / U-BQ(ZN)BH

up to 144 fibres, Euroclass Cca
metal-free, dry interstices, gel-free loose tube,
rodent protection, flame redardant, longitudinally watertight

1 ≤ 12 fibres
2 Loose tube
3 Swelling tape
4 Glass armour
5 Ripcord
6 FR/LS0H sheath

Description

Robust, metal-free fibre optic outdoor and indoor cable with stranded dry loose tubes.
High crush resistance for high transmission reliability.
Easy to handle due to cable construction with dry interstices and gel-free loose tubes.
Longitudinal water-tightness by swelling yarn.
Non-metallic rodent protection.
The two coloured ripcords are easy to identify and enable the safe opening of the cable sheath.
Flame retardant halogen-free FR/LS0H sheath.

  • LAN backbone, access and riser zone.
    Connection cable between the building distributors and/or floor distributors.
    Suitable for laying in cable trays, ducts and vertical shafts.
    Can also be spliced in all FO distributors and joints.
  • Outer sheath material FRNC/LSZH
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Field of application Universal
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Maximum number of fibres 144
  • Fibre colour code IEC 60304
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Cca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
  • Flame Spread IEC 60332-3-24
  • Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
  • UV resistance EN 50289-4-17

Documentation

ENDENLFRCNESIT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

More Information

The impact of water on fibre optic cable

Versions

Article No.StockProductReaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load short term [N]Tensile load continuous [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTINFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19710100CZ FO Universal DLTS 1x12Cca–s1a,d1,a1yellow12E9/125 G.652.D OS211.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910016666OS21251
19618300CZ FO Universal DLTS 2x12Cca–s1a,d1,a1yellow24E9/125 G.652.D OS211.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910018950OS21252
19710600CZ FO Universal DLTS 2x12Cca–s1a,d1,a1turquoise24G50/125 OM311.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910016512OM31252
19618700CZ FO Universal DLTS 2x12Cca–s1a,d1,a1heather violet24G50/125 OM411.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910018813OM41252
19706900CZ FO Universal DLTS 2x12Cca–s1a,d1,a1lime green24G50/125 OM511.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910017038OM51252
19618400CZ FO Universal DLTS 4x12Cca–s1a,d1,a1yellow48E9/125 G.652.D OS211.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910018929OS21254
19710700CZ FO Universal DLTS 4x12Cca–s1a,d1,a1turquoise48G50/125 OM311.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910016482OM31254
19618800CZ FO Universal DLTS 4x12Cca–s1a,d1,a1heather violet48G50/125 OM411.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910018783OM41254
19707000CZ FO Universal DLTS 4x12Cca–s1a,d1,a1lime green48G50/125 OM511.4 mm175 mm15690005000500015000.51 kWh/mby the metre40393910017007OM51254
19710200CZ FO Universal DLTS 6x12Cca–s1a,d1,a1yellow72E9/125 G.652.D OS212.2 mm185 mm16490005000500015000.539 kWh/mby the metre40393910016635OS21266
19710300CZ FO Universal DLTS 8x12Cca–s1a,d1,a1yellow96E9/125 G.652.D OS213.5 mm205 mm19790005000500015000.65 kWh/mby the metre40393910016604OS21288
19710800CZ FO Universal DLTS 8x12Cca–s1a,d1,a1turquoise96G50/125 OM313.5 mm205 mm19790005000500015000.65 kWh/mby the metre40393910016451OM31288
19708800CZ FO Universal DLTS 8x12Cca–s1a,d1,a1heather violet96G50/125 OM413.5 mm205 mm19790005000500015000.65 kWh/mby the metre40393910016734OM41288
19710400CZ FO Universal DLTS 10x12Cca–s1a,d1,a1yellow120E9/125 G.652.D OS214.8 mm225 mm23690005000500015000.788 kWh/mby the metre40393910016574OS2121010
19710500CZ FO Universal DLTS 12x12Cca–s1a,d1,a1yellow144E9/125 G.652.D OS216.3 mm245 mm28890005000500015000.958 kWh/mby the metre40393910016543OS2121212
19710900CZ FO Universal DLTS 12x12Cca–s1a,d1,a1turquoise144G50/125 OM316.3 mm245 mm28890005000500015000.958 kWh/mby the metre40393910016420OM3121212
19708900CZ FO Universal DLTS 12x12Cca–s1a,d1,a1heather violet144G50/125 OM416.3 mm245 mm28890005000500015000.958 kWh/mby the metre40393910016703OM4121212
EN 60332-3-Series superseded by EN 50575