Back to: Universal cable

FO Universal ZGGFR Easy Blow / U-DQ(ZN)BH

Fire resistant, optimized for blowing, up to 24 fibres, Euroclass Dca
metal-free, rodent protection,
in accordance with IEC 60332.1 and IEC 60332.3 C

1 ≤ 24 fibres
2 Loose tube
3 Glass armour
4 Ripcord
5 FR/LS0H sheath (black)

Description

Robust, metal-free fibre optic outdoor and indoor cable with one central loose tube.
Optimized for blowing through thermoplastic ducts:
Its good greasing characteristics, smooth and strong sheath surface and good internal strength provide for an axial linear motion and reduced friction (in comparison with standard indoor/outdoor cables).
Non-metallic rodent protection.
Flame retardant and fire resistant sheath (black) with very low fire load.
The coloured ripcords are easy to identify and enable the safe opening of the cable sheath.

  • For blowing through thermoplastic ducts with blowing lengths of up to 2000 m.
    In Premises cabling for LAN backbones (Campus and Vertical/Riser cabling) as well as for tunnels.
  • Outer sheath material FRNC/LSZH
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Field of application Universal
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Maximum number of fibres 24
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Reaction to fire (Euroclasses) EN 13501-6: Dca
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Flame Propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
  • Flame Spread IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24
  • Smoke Density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
  • UV resistance EN 50289-4-17

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

More Information

The impact of water on fibre optic cable

Versions

Article No. Stock Product Reaction To FireOuter sheath colourNumber of FibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTINFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
19061700DZ FO Universal Easy Blow 1x4 Dca-s2,d1,a1 black 4 E9/125 G.652.D OS2 8.5 mm140 mm85 2500 3000 2000 0.356 kWh/mby the metre 40393910032567 OS2 4 1 1
19182500DZ FO Universal Easy Blow 1x4 Dca-s2,d1,a1 black 4 G50/125 OM3 8.5 mm140 mm85 2500 3000 2000 0.356 kWh/mby the metre 40393910029734 OM3 4 1 1
19036300DZ FO Universal Easy Blow 1x6 Dca-s2,d1,a1 black 6 E9/125 G.652.D OS2 8.5 mm140 mm85 2500 3000 2000 0.356 kWh/mby the metre 40393910032994 OS2 6 1 1
19170000DZ FO Universal Easy Blow 1x8 Dca-s2,d1,a1 black 8 E9/125 G.652.D OS2 8.5 mm140 mm85 2500 3000 2000 0.356 kWh/mby the metre 40393910029949 OS2 8 1 1
19021300DZ FO Universal Easy Blow 1x12 Dca-s2,d1,a1 black 12 E9/125 G.652.D OS2 8.5 mm140 mm85 2500 3000 2000 0.356 kWh/mby the metre 40393910033281 OS2 12 1 1
19021400DZ FO Universal Easy Blow 1x24 Dca-s2,d1,a1 black 24 E9/125 G.652.D OS2 9 mm145 mm92 2500 3000 2000 0.4 kWh/mby the metre 40393910033274 OS2 24 1 1