Back to: Universal cable

FO Universal ZGGFR Safety / U-DQ(ZN)BH

Safety cable E30*, up to 12 fibres
metal-free, water resistant, rodent protection,
in accordance with IEC 60332-1-2 and IEC 60332-3-24
30 minutes System Circuit Integrity* with reference to DIN 4102-12

1 ≤ 12 fibres
2 Flame retardant protective coating
3 Glass armour
4 Ripcord
5 FR/LS0H sheath

Description

Metal-free fibre optic safety cable with one central loose tube, up to 12 fibres.
The optimal combination of flame retardant fibre coating and flame-inhibiting stabilizing elements ensures enhanced functional integrity (System Circuit Integrity*) in case of fire for 30 minutes (transmission of audio, video and 1Gbit/s signals approved by a certified test report).

  • Safety applications in tunnels, underground railways, banks, insurance companies, large-scale industry.
    LAN backbone.
    Indoor and outdoor cabling.
    Can also be installed in cable platforms, trays, ducts and vertical shafts (without System Circuit Integrity*).
    Can be spliced in FO distributors.
  • Installation temperature -10 °C - +50 °C
  • Storage temperature -25 °C - +70 °C
  • Operating temperature -25 °C - +70 °C
  • Outer sheath material FRNC/LSZH
  • Imprint DATWYLER «cable type» «Datwyler designation» «DIN designation» «no. of fibres» «fibre type» «add. text» «batch no.» «meter marks»
  • Circuit Integrity E30
  • Field of application Universal
  • Maximum number of fibres 12
  • * System Circuit Integrity is dependent on installation method. Certified clamps, ducts, conduits, etc. are mandatory.
  • Tensile performance IEC 60794-1-21 E1
  • Crush resistance IEC 60794-1-21 E3
  • Impact IEC 60794-1-21 E4
  • Repeated bending IEC 60794-1-21 E6
  • Torsion IEC 60794-1-21 E7
  • Bend IEC 60794-1-21 E11
  • Temperature cycling IEC 60794-1-22 F1
  • Water penetration IEC 60794-1-22 F5
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2
  • Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
  • Flame spread IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24
  • Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2
  • System circuit integrity with reference to DIN 4102-12, VKF Fire Safety Application No. 24176
  • UV resistance EN 50289-4-17
  • Insulation Integrity (FE180) IEC 60331-11, IEC 60331-25 (FE180), EN 50200 PH30, VDE 0482-200

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

More Information

The impact of water on fibre optic cable

Versions

Article No. Stock Product Outer sheath colourNumber of fibresFibre typeOuter sheath diameter [mm]Bending radius [mm]Weight [kg/km]Tensile load [N]Crush resistance short term [N]Crush resistance continuous [N]Fire load [kWh/m]Packing unitGTIN / EANFibre categoryFibres per loose tubeLoose tube constructionNumber of used loose tubes
187288 FO Universal Safety 1x4 red 4 E9/125 G.652.D OS2 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910074024 OS2 4 1 1
190604 FO Universal Safety 1x4 red 4 G50/125 OM3 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910070521 OM3 4 1 1
193447 FO Universal Safety 1x4 red 4 G50/125 OM4 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910065527 OM4 4 1 1
191867 FO Universal Safety 1x6 red 6 E9/125 G.652.D OS2 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910068610 OS2 6 1 1
191851 FO Universal Safety 1x6 red 6 G50/125 OM3 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910068665 OM3 6 1 1
193448 FO Universal Safety 1x6 red 6 G50/125 OM4 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910065510 OM4 6 1 1
196130 FO Universal Safety 1x8 red 8 E9/125 G.652.D OS2 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910061642 OS2 8 1 1
196120 FO Universal Safety 1x8 red 8 G50/125 OM3 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910061659 OM3 8 1 1
193449 FO Universal Safety 1x8 red 8 G50/125 OM4 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910065503 OM4 8 1 1
190719 FO Universal Safety 1x12 red 12 E9/125 G.652.D OS2 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910070361 OS2 12 1 1
191796 FO Universal Safety 1x12 red 12 G50/125 OM3 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910068795 OM3 12 1 1
193450 FO Universal Safety 1x12 red 12 G50/125 OM4 7.8 120 75 1000 5000 2000 0.301 kWh/mby the metre 40393910065497 OM4 12 1 1