Back to: Copper cables

CU 6052 4P / 2x4P F8

Data cable, F/FTP, Category 6, AWG23, Euroclass Cca
300 MHz

1 Inner conductor: AWG23 Bare copper wire
2 PE insulated conductor: 1.3 mm Ø
3 Screen (pair): Alu PETP foil
4 Overall screen: Alu PETP foil
5 Drain wire: Tinned copper wire
6 Outer sheath: FRNC/LSOH Orange RAL 2003

Description

Electrically and mechanically superior quality Cat.6 data cable – exceeds the requirements of ISO/IEC 11801, IEC 61156-5, EN 50173-1 and EN 50288-5-1.
Good shielding effect due to individually screened pairs and overall foil screen.
Compatible with all current connecting hardware in accordance with EN 50173 and ISO/IEC 11801.

  • Data cable for structured premises cabling.
    For the transmission of digital and analogue voice, video and data signals.
    Suitable for all ICT network applications up to class E applications (250 MHz) in accordance with EN 50173-1 and ISO/IEC 11801.
    Applicable for Power over Ethernet (PoE) / PoE+.
  • Outer sheath material FRNC/LSZH
  • Outer sheath colour orange
  • Category Cat.6
  • Coupling attenuation 65 dB
  • Delay skew 5 ns/100 m
  • Shielding shielded
  • GBit/s Up to 1 Gbit/s
  • Impedance at 100 MHz, ±5Ω 100 Ω
  • Loop resistance at 20 °C 150 Ω/km
  • Near end unbalance attenuation LCL at 1-600 MHz 40 dB
  • NVP % 79
  • Operating capacity 42 pF/m
  • Segregation class c
  • Transfer impedance 1/10/30 MHz 50/100/200 mΩ/m
  • Installation temperature 0 °C - +50 °C
  • Operating temperature -20 °C - +60 °C
  • Imprint DATWYLER «cable type» «additional text» «batch number» «meter marks»
  • Field of application Indoor
  • Wire colour white/blue, white/orange, white/green, white/brown, according to IEC 60189 and IEC 60708
  • AWG 23
  • Minimum bending radius during installation 56 mm
  • Minimum bending radius permanently installed 28 mm
  • Minimal crush resistance / 10cm 1000 N
  • Minimum number of impacts 10
  • Solid / Flex Solid wire
  • Tensile strength (2x4P) 190 N
  • Tensile strength (4P) 95 N
  • Reaction to fire (Euroclasses) EN 13501-6: Cca
  • Smoke density IEC 61034-1/-2, EN 61034-1/-2, VDE 0482-1034-1/-2, AREI-RGIE Art.104-SD
  • Zero halogen no corrosive gases IEC 60754-1/-2, EN 60754-1/-2, VDE 0482-754-1/-2, AREI-RGIE Art.104-SA
  • Flame propagation IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2, AREI-RGIE Art.104-F1
  • Flame spread IEC 60332-3-24, EN 60332-3-24, AREI-RGIE Art.104-F2
  • Cables standard ISO/IEC 61156-5, EN 50288-5-1
  • Cat./Class Cat.6 / Class E
  • PoE IEEE 802.3bt Type 4 (100W)

Documentation

EN DE NL FR CN ES IT
Datasheet Datasheet Datasheet Datasheet Datasheet file-icon Datasheet Datasheet

Versions

Article No. Stock Product AWGReaction to fireDimensions n x p x [mm (AWG)]Number of pairsNumber of coresDiameter mmOuter sheath dimensions [mm]CU rate [kg/km]Weight [kg/km]Fire load [kWh/m]Number of cablesPacking unitGTIN / EAN
18851200CK CU 6052 4P AWG23 Cca-s1a,d1,a1 4 x 2 x 0.55 (AWG23) 4 2 0.55 7 20.0 49 0.144 kWh/m1 1000 m drum 40393910034370